Ten‐year retrospective cohort analysis of ventricular assist device infections

Background The number of patients treated by ventricular assist devices (VAD) and the duration of VAD treatment is increasing. One of the main complications in terms of morbidity and mortality for VAD patients are microbial infections. With this study, we aimed to investigate the epidemiology and mi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Artificial organs 2023-05, Vol.47 (5), p.898-905
Hauptverfasser: Spano, Giancarlo, Buffle, Eric, Walti, Laura Naëmi, Mihalj, Maks, Cameron, David R., Martinelli, Michele, Fürholz, Monika, Que, Yok‐Ai, Hayward, Christopher, Reineke, David, Hunziker, Lukas, Schnegg, Bruno
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background The number of patients treated by ventricular assist devices (VAD) and the duration of VAD treatment is increasing. One of the main complications in terms of morbidity and mortality for VAD patients are microbial infections. With this study, we aimed to investigate the epidemiology and microbiological characteristics of infections occurring in a VAD population to identify modifiable factors. Methods We retrospectively analyzed patient characteristics, treatments and outcomes of VAD‐specific/related infections. All patients implanted in our institution with a continuous flow VAD between January 2009 and January 2019 were included. Risk factors for VAD infection were assessed using simple and multiple linear regressions. Results Of the 104 patients screened, 99 were included in the analysis, the majority of which were men (78%). At implantation, the mean age was 56 years and the median time on VAD support was 541 days. The overall infection rate per year per patient was 1.4. Forty‐seven patients (60%) suffered from VAD‐specific/related infection. Half of all infection episodes occurred in the first 4 months but the proportion of VAD‐specific/related infection was higher after the first 4 months (74% of all infection). Using regression models, no patient specific risk factors were associated with VAD‐specific/related infections. Conclusion No predictive factors for infection during VAD support were identified in this study. By extension, diabetes, renal insufficiency, age or high BMI are not sufficient to deny a patient access to ventricular support. The number of patients treated by ventricular assist devices (VAD) and the duration of VAD treatment is increasing. One of the main complications in terms of morbidity and mortality for VAD patients are microbial infections. With this study, we investigated the epidemiology and microbiological characteristics of infections occurring in a VAD population to identify modifiable factors.
ISSN:0160-564X
1525-1594
DOI:10.1111/aor.14477