Does the ESD-failure current obtained by transmission-line pulsing always correlate to human body model tests?
Two different technologies serve as examples that the degree of correlation between ESD-failure currents obtained by transmission-line pulsing (TLP) and human body model (HBM) is a matter of the technology under investigation. Stressing a device with HBM or TLP can lead to different failure modes an...
Gespeichert in:
Veröffentlicht in: | Microelectronics and reliability 1998-11, Vol.38 (11), p.1773-1780 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Two different technologies serve as examples that the degree of correlation between ESD-failure currents obtained by transmission-line pulsing (TLP) and human body model (HBM) is a matter of the technology under investigation. Stressing a device with HBM or TLP can lead to different failure modes and, as a consequence, to a miscorrelation between the two test methods. Optimising a technology or a protection device only by means of TLP can easily lead to false conclusions. |
---|---|