Pseudo multishot echo‐planar imaging for geometric distortion improvement

Conventional echo‐planar imaging (EPI) uses a radiofrequency pulse for excitation and a prolonged echo train to sample k space, while off‐resonance and T2* decay effects caused by magnetic susceptibility variation accumulate within each echo, leading to geometric distortion. Multishot EPI methods, w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:NMR in biomedicine 2023-05, Vol.36 (5), p.e4885-n/a
Hauptverfasser: Chen, Hao, Dai, Ke, Bao, Jianfeng, Zhong, Sijie, Hu, Chenxi, Liu, Yiling, Zhang, Zhiyong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Conventional echo‐planar imaging (EPI) uses a radiofrequency pulse for excitation and a prolonged echo train to sample k space, while off‐resonance and T2* decay effects caused by magnetic susceptibility variation accumulate within each echo, leading to geometric distortion. Multishot EPI methods, which divide k space into segments, can shorten the effective echo spacing and reduce the distortion on EPI images. But multiple shots cost longer scan time and render susceptibility to motion. In this study, we propose a new “multishot” EPI method termed pseudo multishot EPI (pmsEPI), in which phase‐encoding lines are segmented as in multishot EPI but are collected within a single shot. With the magnetization divided into different pathways via interleaved excitation instead of refocusing in a single long echo train, the total phase error accumulation is reduced in each segmented acquisition, thereby improving distortion of the resultant EPI image. The performance of the pmsEPI method is demonstrated by phantom and in vivo brain experiments on a 3‐T scanner. The experimental results show that the distortion displacements of pmsEPI acquisition compared with conventional EPI decrease by 50% with two pseudo shots and 66% with three pseudo shots, validating the ability of the method to obtain images with reduced distortion in a single shot, although magnetization splitting may induce more than 40% SNR loss and minor artifacts. Specifically, the ability of pmsEPI in diffusion‐weighted imaging with different trajectory options is highlighted, and the flexibility is demonstrated in a single‐shot blip up and down acquisition. EPI is sensitive to field inhomogeneities, leading to geometric distortion of images. We proposed a “pseudo” multishot EPI method to reduce geometric distortion. Via interleaved excitation, multisegment k space can be collected within a single shot. More than 50% distortion decrease can be obtained, compared with the conventional method.
ISSN:0952-3480
1099-1492
DOI:10.1002/nbm.4885