T1 relaxation of bound and pore water in cortical bone

MRI measures of bound and/or pore water concentration in cortical bone offer potential diagnostics of bone fracture risk. The transverse relaxation characteristics of both bound and pore water are relatively well understood and have been used to design clinical MRI pulse sequences to image each wate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:NMR in biomedicine 2023-05, Vol.36 (5), p.e4878-n/a
Hauptverfasser: Ketsiri, Thammathida, Uppuganti, Sasidhar, Harkins, Kevin D., Gochberg, Daniel F., Nyman, Jeffry S., Does, Mark D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:MRI measures of bound and/or pore water concentration in cortical bone offer potential diagnostics of bone fracture risk. The transverse relaxation characteristics of both bound and pore water are relatively well understood and have been used to design clinical MRI pulse sequences to image each water pool quantitatively. However, these methods are also sensitive to longitudinal relaxation characteristics, which have been less well studied. Here, spectroscopic relaxometry measurements of 31 human cortical bone specimens provided a more detailed picture of T1 of both bound and pore water. The results included mean, standard deviation, and range of T1 spectra from both bound and pore water, as well as novel presentations of the 2D T1−T2 distribution of pore water. Importantly, for each sample the pore water T1 spectrum was found to span more than one order of magnitude and varied substantially across the 31 sample studies. Because many existing methods assume pore water T1 to be mono‐exponential and constant across individuals, the results were used to compute the potential effect neglecting this intra‐ and intersample T1 variation on accurate MRI measurement of both bound and pore water concentrations. The greatest effect was found for adiabatic inversion recovery (AIR) based measurements of bound water concentration, which showed an average of 8.8% and as much as 37% error when using a common mono‐exponential assumption of pore water T1. Despite these errors, the simulated AIR measurements were still moderately well correlated with the bound water concentrations derived from the spectroscopic data. Spectroscopic relaxometry of 31 human cortical bone specimens provided a detailed picture of longitudinal relaxation of both the bound and porew water signal components. This figure show one‐dimensional presentations of the mean, standard deviation (SD), and range across samples of the bound and pore water T1 spectra. The bound water T1 is narrowly distributed and highly reproducible across individuals, while the pore water T1 varies widely within and across individuals.
ISSN:0952-3480
1099-1492
DOI:10.1002/nbm.4878