Voltammetric determination of Molnupiravir used in treatment of the COVID-19 at magnetite nanoparticle modified carbon paste electrode

To reduce the progression of the viral process in patients infected with COVID-19, new treatments and drug active substances are needed. One of these drugs is Molnupiravir (MNP) which has a direct antiviral effect and has also proven to be highly effective in reducing the azopharyngeal SARS-CoV-2 in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Microchemical journal 2023-01, Vol.184, p.108195, Article 108195
Hauptverfasser: Vural, Kader, Karakaya, Serkan, Dilgin, Didem Giray, Gökçel, Hatice İsmet, Dilgin, Yusuf
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To reduce the progression of the viral process in patients infected with COVID-19, new treatments and drug active substances are needed. One of these drugs is Molnupiravir (MNP) which has a direct antiviral effect and has also proven to be highly effective in reducing the azopharyngeal SARS-CoV-2 infectious virus and viral RNA. Due to the importance and frequent use of this drug in the treatment of COVID-19, its accurate, quick, and cheap detection in pharmaceutical or biological samples is crucial. In this work, electrochemical behavior and sensitive voltammetric determination of MNP are described using a magnetite nanoparticle modified carbon paste electrode (Fe O @CPE) for the first time. Fe O nanoparticles (NPs) were characterized by recording their transmission electron microscopy (TEM) images, energy dispersive X-ray (EDX), and X-ray diffraction (XRD) spectra. Cyclic voltammetric measurements showed that MNP was irreversibly oxidized at Fe O @CPE at 760 mV in pH 2.0 Britton Robinson buffer solution (BRBS). The peak current of MNP was increased approximately threefold at Fe O @CPE compared to bare CPE due to a good electrocatalytic efficiency of Fe O NPs. According to differential pulse voltammetric studies, the fabricated electrode exhibited a linear range (LR) between 0.25 and 750 µM with sensitivity and limit of detection (LOD) of 4591.0 µA mM  cm and 0.05 µM, respectively. On the other hand, although lower sensitivity (327.3 µA mM  cm ) was obtained from CV compared to DPV, a wider linear calibration curve between 0.25 and 1500 µM was obtained in CV. Studies performed in tablet samples confirmed that the Fe O @CPE exhibits high applicability for selective and accurate voltammetric determination of MNP in real samples.
ISSN:0026-265X
DOI:10.1016/j.microc.2022.108195