Robustly optimized hybrid intensity-modulated proton therapy for craniospinal irradiation

Aim: The aim of the study was to investigate the hybrid robust optimization planning approach in intensity-modulated proton therapy (IMPT) of craniospinal irradiation (CSI). Subjects and Methods: Five IMPT-based adult CSI plans in supine position were created using Raystation treatment planning syst...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cancer research and therapeutics 2022-10, Vol.18 (6), p.1597-1603
Hauptverfasser: Noufal, Manthala, Sharma, Shamurailatpam, Krishnan, Ganapathy, Sawant, Mayur, Gaikwad, Utpal, Jalali, Rakesh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Aim: The aim of the study was to investigate the hybrid robust optimization planning approach in intensity-modulated proton therapy (IMPT) of craniospinal irradiation (CSI). Subjects and Methods: Five IMPT-based adult CSI plans in supine position were created using Raystation treatment planning system (TPS) modelled for Proteus plus proton therapy system. A hybrid planning strategy was implemented, where clinical target volume was robustly optimized (RB) for set up uncertainties and planning target volume was optimized for target coverage using minimax algorithm in the TPS. Beam angle selection, optimization, and dose calculation approach were carefully performed to ensure optimum organ at risk (OAR) sparing, even with potential setup and range errors. The complementary dose gradients in junctions were generated using spot assignment and RB technique. Dosimetric outcomes in both nominal plan and the 16 error scenarios (±3 mm setup and 3.5% range) were analyzed using standard dose volume histogram. Results: This planning approach resulted in a homogeneous dose distribution in the target volume of CSI, including the junction regions, by explicitly reducing number of robust optimization scenarios. The proposed technique was also able to achieve excellent coverage to cribriform plate with lower lens doses and minimal dose to other OARs. Target and OAR doses in the nominal plans as well as in the worst case scenarios with setup and range errors were able to meet the predefined clinical goal. Conclusions: This proposed planning technique is efficient, robust against the uncertainties. It could be adopted in other proton therapy centers.
ISSN:0973-1482
1998-4138
DOI:10.4103/jcrt.JCRT_740_20