Effectiveness of tuned liquid dampers under wind excitation

Full-scale measurements of the wind-induced responses of four buildings (two airport towers, an observatory tower and a highrise hotel) were conducted to prove the efficiency of tuned liquid dampers (TLDs). The damping ratios of the buildings with and without TLD were evaluated by both the run-down...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Engineering structures 1995, Vol.17 (9), p.609-621
Hauptverfasser: Tamura, Yukio, Fujii, Kunio, Ohtsuki, Tamio, Wakahara, Toshihiro, Kohsaka, Ryuichi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Full-scale measurements of the wind-induced responses of four buildings (two airport towers, an observatory tower and a highrise hotel) were conducted to prove the efficiency of tuned liquid dampers (TLDs). The damping ratios of the buildings with and without TLD were evaluated by both the run-down test technique and the random decrement technique. The wind-induced responses of the buildings were measured before and after installation of TLDs. The exceedance frequency of the response over the human perception thresholds was also examined. The results obtained in this study demonstrate that the TLDs could significantly improve the serviceability of the buildings.
ISSN:0141-0296
1873-7323
DOI:10.1016/0141-0296(95)00031-2