Sensitive Zika biomarker detection assisted by quantum dot-modified electrochemical immunosensing platform
We report the development of a new nanostructured electrochemical immunosensing platform for the detection of the Zika virus envelope protein (EP-ZIKV). For this, quantum dots (QDs) were explored in combination with screen-printed carbon electrodes (SPCEs) functionalized with a conductor polymeric f...
Gespeichert in:
Veröffentlicht in: | Colloids and surfaces, B, Biointerfaces B, Biointerfaces, 2023-01, Vol.221, p.112984-112984, Article 112984 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report the development of a new nanostructured electrochemical immunosensing platform for the detection of the Zika virus envelope protein (EP-ZIKV). For this, quantum dots (QDs) were explored in combination with screen-printed carbon electrodes (SPCEs) functionalized with a conductor polymeric film, formed from 2-(1H-pyrrol-1-yl)ethanamine (Pyam), and anti-EP DIII ZIKV antibodies. Carboxylated CdTe QDs were synthesized, characterized by optical and structural techniques, and covalently immobilized onto the SPCE/PPyam surface. Then, anti-EP ZIKV antibodies were also covalently conjugated to QDs. All stages of platform assembly were evaluated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The detection of EP-ZIKV was performed by differential pulse voltammetry (DPV). Results indicated that QDs were efficiently immobilized, and did not show oxidation, under the conditions evaluated, for at least 7 months. Anti-EP ZIKV antibodies were effectively immobilized on the PPyam/QDs surface, even after 2 months of electrode storage. The platform enabled the detection of EP-ZIKV with high sensitivity using minimal sample volumes (LOD = 0.1 ng mL-1 and LOQ = 0.4 ng mL-1). The platform was also able to detect EP-ZIKV in spiked serum samples. Moreover, the platform showed specificity, not detecting the EP-DENV 3 nor a mixture of four DENV serotypes antigens. Thus, the proposed combination favored the development of a sensitive immunosensing platform, promising for the detection of Zika in the viremic phase, which also holds potential for transposition to other arboviruses.
[Display omitted]
•An electrochemical platform based on SPCE, QDs and polypyrrole film for Zika detection was developed.•The polymer film facilitated the charge transfer process, eliminating the need for previous SPCE treatments.•QDs immobilized on SPCEs presented (electro)chemical stability over time.•The platform enabled a specific and highly sensitive detection of the ZIKV envelope protein. |
---|---|
ISSN: | 0927-7765 1873-4367 |
DOI: | 10.1016/j.colsurfb.2022.112984 |