Comparative Safety of Transcatheter LAAO With the First-Generation Watchman and Next-Generation Watchman FLX Devices

Procedural complications limit the clinical benefit of transcatheter left atrial appendage occlusion (LAAO). Next-generation devices incorporate design modifications intended to improve procedural safety, but their clinical impact has not been described. The aim of this study was to compare in-hospi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JACC. Cardiovascular interventions 2022-11, Vol.15 (21), p.2115-2123
Hauptverfasser: Price, Matthew J., Friedman, Daniel J., Du, Chengan, Wang, Youngfei, Lin, Zhenqiu, Curtis, Jeptha P., Freeman, James V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Procedural complications limit the clinical benefit of transcatheter left atrial appendage occlusion (LAAO). Next-generation devices incorporate design modifications intended to improve procedural safety, but their clinical impact has not been described. The aim of this study was to compare in-hospital outcomes for the Watchman FLX with the predicate Watchman 2.5 device. The National Cardiovascular Data Registry LAAO Registry was used to identify patients who received the Watchman FLX and an identical number of patients receiving the Watchman 2.5 at the same sites directly preceding the first Watchman FLX case at each site. The primary endpoint was in-hospital major adverse events (MAE), defined as a composite of death, cardiac arrest, stroke, transient ischemic attack, intracranial hemorrhage, systemic arterial embolism, major bleeding, major vascular complication, myocardial infarction, pericardial effusion requiring intervention (percutaneous or surgical), and device embolization. A secondary analysis was performed using 2:1 propensity score matching of patients receiving the Watchman 2.5 or Watchman FLX. The study cohort consisted of 27,013 patients receiving each device. The rate of in-hospital MAE was significantly lower for the Watchman FLX compared with the Watchman 2.5 (1.35% vs 2.40%; adjusted OR: 0.57; 95% CI: 0.50-0.65; P < 0.0001), driven largely by fewer pericardial effusions requiring intervention (0.42% vs 1.23%; adjusted OR: 0.34; 95% CI: 0.28-0.42; P < 0.0001). The Watchman FLX was also associated with significant lower rates of the individual endpoints of in-hospital mortality (0.12% vs 0.24%; P < 0.0001), major bleeding (1.08% vs 2.05%; P 
ISSN:1936-8798
1876-7605
DOI:10.1016/j.jcin.2022.09.002