Does the available interocclusal space influence the accuracy of the maxillomandibular relationship captured with an intraoral scanner?
The accuracy of a maxillomandibular relationship acquired by intraoral scanners (IOSs) has been previously analyzed; however, the impact of the interocclusal space on the accuracy of the maxillomandibular relationship remains unknown. The purpose of this in vitro investigation was to evaluate the in...
Gespeichert in:
Veröffentlicht in: | The Journal of prosthetic dentistry 2024-08, Vol.132 (2), p.435-440 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The accuracy of a maxillomandibular relationship acquired by intraoral scanners (IOSs) has been previously analyzed; however, the impact of the interocclusal space on the accuracy of the maxillomandibular relationship remains unknown.
The purpose of this in vitro investigation was to evaluate the influence of the interocclusal space (0, 1, 2, 3, or 4 degrees of incisal opening in the articulator) on the accuracy of the maxillomandibular relationship captured with an IOS.
Markers were attached to the first molars and canines of maxillary and mandibular diagnostic casts, which were mounted on a semi-adjustable articulator, and digital scans were acquired (TRIOS 4). Both digital scans were duplicated 100 times and distributed into 5 groups depending on the incisal pin opening in the articulator (n=20): 0 (Group 0), 1 (Group 1), 2 (Group 2), 3 (Group 3), and 4 degrees (Group 4). In Group 0 (control), the casts were maintained in maximum intercuspation (MIP) with the incisal pin of the articulator set at 0 degrees. Then, a bilateral virtual occlusal record was acquired and automatically processed by using the IOS software program. A laboratory scanner (Medit T500) was used to digitize the mounted casts. The same procedures were completed in Groups 1, 2, 3, and 4 but with the incisal pin set at 1, 2, 3, and 4 degrees respectively. The interlandmark distances were used to calculate the discrepancies between the control and groups tested. One-way analysis of variance (ANOVA) and pairwise comparison Tukey HSD tests were used to inspect the data (α=.05).
The interocclusal space available when capturing the occlusal records affected the trueness of the maxillomandibular virtual relationship measured (P |
---|---|
ISSN: | 0022-3913 1097-6841 1097-6841 |
DOI: | 10.1016/j.prosdent.2022.09.004 |