Viscosity of the CaO-CaF sub 2 System Containing Chromium Oxide
Viscosity of the CaO-CaF sub 2 -Cr sub 2 O sub 3 system (15% < CaO < 25%, 75% < CaF sub 2 < 85%, 0% < Cr sub 2 O sub 3 , 10%) in steel refining was measured by the vibrational resonant amplitude method. From the experimental data on slags viscosity as a function of temperature, liquid...
Gespeichert in:
Veröffentlicht in: | ISIJ international 1994-09, Vol.34 (9), p.773-775 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Viscosity of the CaO-CaF sub 2 -Cr sub 2 O sub 3 system (15% < CaO < 25%, 75% < CaF sub 2 < 85%, 0% < Cr sub 2 O sub 3 , 10%) in steel refining was measured by the vibrational resonant amplitude method. From the experimental data on slags viscosity as a function of temperature, liquidus temperatures were determined. Viscosities and liquidus temperatures were found to increase with an increase in the chromium oxide concentration in the slag. |
---|---|
ISSN: | 0915-1559 |