Influence of digital implant analog design on the positional trueness of an analog in additively manufactured models: An in‐vitro study

Background Limited evidence exists regarding the accuracy of implant analog position in printed models, particularly when implant analogs with varying designs are used. Purpose To evaluate the effect of digital implant analog (DIA) design on the trueness of their position in additively manufactured...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical implant dentistry and related research 2022-12, Vol.24 (6), p.821-830
Hauptverfasser: Mata‐Mata, Severino J., Donmez, Mustafa Borga, Meirelles, Luiz, Johnston, William Michael, Yilmaz, Burak
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Limited evidence exists regarding the accuracy of implant analog position in printed models, particularly when implant analogs with varying designs are used. Purpose To evaluate the effect of digital implant analog (DIA) design on the trueness of their position in additively manufactured digital implant models (DIMs) and to compare with that of a conventional implant analog in a stone cast. Materials and Methods A dentate maxillary model with a conventional implant analog (Nobel Biocare Implant Replica 4.3 mm CC RP) at left second premolar site was digitized by using a laboratory scanner (3Shape D2000) and a (SB) scan body to generate the master standard tessellation language (STL) file (M0). 12 custom trays were fabricated on M0 file and conventional polyvinylsiloxane impressions of the model were made. All impressions were poured after inserting conventional implant analogs (Nobel RP Implant Replica) (Group A). Model was then digitized with an intraoral scanner (TRIOS 3) and the same SB, and DIMs with three different DIA designs (Nobel Biocare [Group B], Elos [Group C], and NT‐trading [Group D]) were generated (Dental System‐Model Builder). 12 DIMs of each design were additively manufactured and corresponding DIAs were inserted. All models were digitized by using the same laboratory scanner and SB, and these STLs were transferred to a 3D analysis software (Geomagic Control X), where the STL files of the models were superimposed over M0. Linear and 3D deviations at three selected points on SB (implant‐abutment connection, most cervical point on SB, and most coronal point on SB) as well as angular deviations on two planes (buccolingual and mesiodistal) were calculated. Analysis of variance (ANOVA) and Bonferroni corrected t‐tests were used to analyze the trueness of implant analog positions (α = 0.05). Results The interaction of main effects significantly affected linear (p 
ISSN:1523-0899
1708-8208
DOI:10.1111/cid.13137