Multiple hot-film sensor array calibration and skin friction measurement
A method for the calibration of closely spaced multiple hot-film sensor (MHFS) arrays of nickel-on-polyimide-substrate type was presented in this paper. The hot-film sensors were calibrated individually and in situ against the values of the wall-shear stresses determined from boundary-layer velocity...
Gespeichert in:
Veröffentlicht in: | Experiments in fluids 2002, Vol.32 (1), p.37-43 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A method for the calibration of closely spaced multiple hot-film sensor (MHFS) arrays of nickel-on-polyimide-substrate type was presented in this paper. The hot-film sensors were calibrated individually and in situ against the values of the wall-shear stresses determined from boundary-layer velocity profiles (developed on the front portion of a circular cylinder) through a specially designed wall-mounted hot-wire probe. The accuracy and feasibility of the present method was examined through the subsequent measurements of the skin-friction distributions on a circular cylinder (including the removal and bonding of the calibrated MHFS from a 10-cm diameter calibration cylinder and onto the surface of a 8-cm diameter test cylinder) and comparison of their consistency with the published results. The present MHFS calibration method is important in the non-intrusive multipoint measurements of the mean skin friction along the surfaces of two-dimensional aerodynamic objects of interest. (Author) |
---|---|
ISSN: | 0723-4864 1432-1114 |
DOI: | 10.1007/s003480200004 |