Double peak axial length measurement signal in cataract patients with epiretinal membrane

Purpose To evaluate the accuracy of axial length (AL) measurement for intraocular lens (IOL) calculation in patients with cataract and epiretinal membrane (ERM). Methods This prospective, cross-sectional study was performed in cataract patients with ERM. All subjects were sent for standard optical b...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International ophthalmology 2023-04, Vol.43 (4), p.1337-1343
Hauptverfasser: Chonpimai, Pratuangsri, Chirapapaisan, Chareenun, Srivannaboon, Sabong, Loket, Siriwan, Nujoi, Waree, Dongngam, Somthin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose To evaluate the accuracy of axial length (AL) measurement for intraocular lens (IOL) calculation in patients with cataract and epiretinal membrane (ERM). Methods This prospective, cross-sectional study was performed in cataract patients with ERM. All subjects were sent for standard optical biometry, prepared for cataract surgery. Signals of AL measurement were detected as double peaks and recorded as AL1 (first peak), and AL2 (second peak). The IOL power was calculated from AL1 and AL2, and reported as IOL1 and IOL2. The IOL2 was chosen for cataract surgery in all cases. Postoperative predictive errors were compared between IOL1 and IOL2. Results Thirty-seven eyes from 37 patients were included. Mean AL1 was significantly shorter than AL2 (23.13 ± 1.28 vs. 23.60 ± 1.34 mm, p  
ISSN:1573-2630
0165-5701
1573-2630
DOI:10.1007/s10792-022-02531-y