Shielding factors of grain oriented 3% SiFe cylinders

We have measured the magnetic shielding factor and permeability of 3% SiFe cylinders with various diameters under the same test frequency, magnetization level, and geometry conditions. The measured shielding factor has been compared with the estimated one by using the measured permeability for the s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on magnetics 1999-09, Vol.35 (5), p.3454-3456
Hauptverfasser: CHUNG, Y.-C, WOO, B.-C, PARK, D.-C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have measured the magnetic shielding factor and permeability of 3% SiFe cylinders with various diameters under the same test frequency, magnetization level, and geometry conditions. The measured shielding factor has been compared with the estimated one by using the measured permeability for the single- and double-layered cylinders. It is found that the simple permeability measurement of the cylinder in itself is useful for the prediction of a magnetic shielding factor.
ISSN:0018-9464
1941-0069
DOI:10.1109/20.800555