Shielding factors of grain oriented 3% SiFe cylinders
We have measured the magnetic shielding factor and permeability of 3% SiFe cylinders with various diameters under the same test frequency, magnetization level, and geometry conditions. The measured shielding factor has been compared with the estimated one by using the measured permeability for the s...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on magnetics 1999-09, Vol.35 (5), p.3454-3456 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We have measured the magnetic shielding factor and permeability of 3% SiFe cylinders with various diameters under the same test frequency, magnetization level, and geometry conditions. The measured shielding factor has been compared with the estimated one by using the measured permeability for the single- and double-layered cylinders. It is found that the simple permeability measurement of the cylinder in itself is useful for the prediction of a magnetic shielding factor. |
---|---|
ISSN: | 0018-9464 1941-0069 |
DOI: | 10.1109/20.800555 |