Cancellation of load regulation in low drop-out regulators
A method for cancelling load regulation, based on level shifting the reference, is proposed. In this architecture, the load current is monitored, sensed, and used to dynamically adapt the effective value of the reference voltage. The proposed architecture reduced a 2.5% load regulation droop to a me...
Gespeichert in:
Veröffentlicht in: | Electronics letters 2002-10, Vol.38 (22), p.1300-1302 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A method for cancelling load regulation, based on level shifting the reference, is proposed. In this architecture, the load current is monitored, sensed, and used to dynamically adapt the effective value of the reference voltage. The proposed architecture reduced a 2.5% load regulation droop to a mere 0.2%, without compromising system stability. |
---|---|
ISSN: | 0013-5194 1350-911X |
DOI: | 10.1049/el:20020909 |