Pulsed field ablation for pulmonary vein isolation: real-world experience and characterization of the antral lesion size compared with cryoballoon ablation

Background Pulsed field ablation (PFA) is a new, non-thermal technology in the treatment of atrial fibrillation (AF). Early investigations have shown a promising safety profile with durable pulmonary vein isolation (PVI) and large antral lesions. However, clinical data remains scarce. Methods We inv...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of interventional cardiac electrophysiology 2023-04, Vol.66 (3), p.567-575
Hauptverfasser: Blockhaus, Christian, Guelker, Jan-Erik, Feyen, Ludger, Bufe, Alexander, Seyfarth, Melchior, Shin, Dong-In
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Pulsed field ablation (PFA) is a new, non-thermal technology in the treatment of atrial fibrillation (AF). Early investigations have shown a promising safety profile with durable pulmonary vein isolation (PVI) and large antral lesions. However, clinical data remains scarce. Methods We investigated a cohort of 43 patients. Twenty-three patients underwent PVI with PFA in our hospital and we analyzed them with regard to procedural characteristics and with regard to the size of acute antral lesion which was estimated by using an electroanatomical map of the left atrium (LA). We compared these data with data of 20 patients who had undergone cryoballon (CB) PVI in our hospital. Results We could show acute isolation of all veins in all patients (100% PFA, 100% CB). Post-ablation high-density mapping revealed no early reconnection (0%). The acute antral lesion size of PFA was significantly higher compared to the CB (67.03 ± 12.69% vs. 57.39 ± 10.91%, p  = 0.01). In the PFA group, we found no acute phrenic nerve injury, no major or minor bleeding, and no tamponade but one (4.34%) patient suffered from a stroke. Transient hypotension was observed frequently as well as transient bradycardia or asystole episodes requiring right ventricular pacing. In the CB group, no complications occurred. Furthermore, we discuss practical issues on PFA procedures. Conclusions PFA is a promising technology with high acute PV isolation rate and large antral lesions compared to CB. However, larger trials with more patients and data on long-term freedom of AF but also complications are needed.
ISSN:1383-875X
1572-8595
DOI:10.1007/s10840-022-01359-x