Heat transfer for diode side-pumped YAG slabs

Thermal heating is a major limiting factor in scaling the average power of a solid-state laser. The heat transfer coefficient is affected by the coolant flow rate, the physical properties of the laser slab and the coolant, and the pumping cavity geometry. The relationship between the heating effects...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics and laser technology 1999-10, Vol.31 (7), p.521-528
Hauptverfasser: Xie, Wenjie, Tam, Siu.-Chung, Yang, Hongru, Gu, Jianhui, Zhao, Gang, Lam, Yee-Loy, Tan, Wilson
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Thermal heating is a major limiting factor in scaling the average power of a solid-state laser. The heat transfer coefficient is affected by the coolant flow rate, the physical properties of the laser slab and the coolant, and the pumping cavity geometry. The relationship between the heating effects and the heat transfer coefficient has been studied by considering the variations of thermal conductivity and expansion coefficient of the laser slab with temperature. It is concluded that different heat transfer coefficients should be adopted according to different heat intensities inside the laser slabs in order to obtain better pumping input as well as to optimize the cooling effects.
ISSN:0030-3992
1879-2545
DOI:10.1016/S0030-3992(99)00111-5