Multicentric evaluation of the variability of digital morphology performances also respect to the reference methods by optical microscopy

Introduction Despite the important diagnostic role of peripheral blood morphology, cell classification is subjective. Automated image‐processing systems (AIS) provide more accurate and objective morphological evaluation. The aims of this multicenter study were the evaluation of the intra and inter‐l...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of laboratory hematology 2022-12, Vol.44 (6), p.1040-1049
Hauptverfasser: Da Rin, Giorgio, Seghezzi, Michela, Padoan, Andrea, Pajola, Rachele, Bengiamo, Anna, Di Fabio, Anna Maria, Dima, Francesco, Fanelli, Alessandra, Francione, Sara, Germagnoli, Luca, Lorubbio, Maria, Marzoni, Alessandro, Pipitone, Silvia, Rolla, Roberta, Bagorria Vaca, Maria del Carmen, Bartolini, Andrea, Bonato, Lisa, Sciacovelli, Laura, Buoro, Sabrina
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction Despite the important diagnostic role of peripheral blood morphology, cell classification is subjective. Automated image‐processing systems (AIS) provide more accurate and objective morphological evaluation. The aims of this multicenter study were the evaluation of the intra and inter‐laboratory variation between different AIS in cell pre‐classification and after reclassification, compared with manual optical microscopy, the reference method. Methods Six peripheral blood samples were included in this study, for each sample, 70 May‐Grunwald and Giemsa stained PB smears were prepared from each specimen and 10 slides were delivered to the seven laboratories involved. Smears were processed by both optical microscopy (OM) and AIS. In addition, the assessment times of both methods were recorded. Results Within‐laboratory Reproducibility ranged between 4.76% and 153.78%; between‐laboratory Precision ranged between 2.10% and 82.2%, while Total Imprecision ranged between 5.21% and 20.60%. The relative Bland Altman bias ranged between −0.01% and 20.60%. The mean of assessment times were 326 ± 110 s and 191 ± 68 s for AIS post reclassification and OM, respectively. Conclusions AIS can be helpful when the number of cell counted are low and can give advantages in terms of efficiency, objectivity and time saving in the morphological analysis of blood cells. They can also help in the interpretation of some morphological features and can serve as learning and investigation tools.
ISSN:1751-5521
1751-553X
DOI:10.1111/ijlh.13943