Incidence and characteristics of errors detected by a short team briefing in pediatric anesthesia

Background In our institution, a modified WHO surgical safety checklist was implemented more than ten years ago. In retrospect, we noticed that pediatric anesthesia was underrepresented in our surgical safety checklist modification. Therefore, we added a standardized team briefing (pedSOAP‐M) immedi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pediatric anesthesia 2022-10, Vol.32 (10), p.1144-1150
Hauptverfasser: Keil, Oliver, Brunsmann, Katja, Boethig, Dietmar, Dennhardt, Nils, Eismann, Hendrik, Girke, Stefan, Horke, Alexander, Nickel, Katja, Rigterink, Vanessa, Sümpelmann, Robert, Beck, Christiane E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background In our institution, a modified WHO surgical safety checklist was implemented more than ten years ago. In retrospect, we noticed that pediatric anesthesia was underrepresented in our surgical safety checklist modification. Therefore, we added a standardized team briefing (pedSOAP‐M) immediately before induction of anesthesia and hypothesized that the use of this checklist was effective to detect relevant errors with potentially harmful consequences. Aims The primary aim was to assess the incidence and characteristics of the detected errors, and the secondary aim was to identify factors influencing error detection. Methods This prospective observational study was performed between November 2020 and October 2021 in five operation rooms at the Children's Hospital of Hannover Medical School, Germany. The subcategories of the pedSOAP‐M checklist were suction, oxygen, airway, pharmaceuticals, and monitoring. Demographic and procedure‐related data and the briefing results were documented anonymously and undated, using a standardized case report form. Results We enrolled 1030 and analyzed 1025 patients (aged 0–18 years). Relevant errors were detected in 111 (10.8%) cases (suction 2.5%, oxygen 3.0%, airway 0.2%, pharmaceuticals 2.4%, monitoring 3.0%). In the pharmaceuticals subcategory, the most common error was entering a wrong patient weight into the perfusor syringe pumps. Experienced anesthetists detected significantly more errors than less experienced ones. Conclusion The briefing tool pedSOAP‐M was effective in detecting relevant errors with potentially harmful consequences. The presence of an experienced anesthetist was associated with a higher efficacy of the briefing. Particular attention should be given to entering patient weight into the anesthesia workstation and the perfusor syringe pumps.
ISSN:1155-5645
1460-9592
DOI:10.1111/pan.14535