Conductor pitch effect on an eddy current loss of the superconducting power cable using the disassembled cable "N" data
The origin of the difference between measured AC loss and that of the short sample test has been studied. The axial field due to disordered pitch of conductor and shield tapes has a trivial effect on the eddy current loss in the stabilizer. The displacement of the current direction on the conductor...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 1999-06, Vol.9 (2), p.1277-1280 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The origin of the difference between measured AC loss and that of the short sample test has been studied. The axial field due to disordered pitch of conductor and shield tapes has a trivial effect on the eddy current loss in the stabilizer. The displacement of the current direction on the conductor from its lay angle makes comparable eddy current loss. |
---|---|
ISSN: | 1051-8223 1558-2515 |