Development of a scatter correction technique for planar 99mTc-MAA imaging to improve accuracy in lung shunt fraction estimation

•Geometric mean method shown to greatly overestimate LSF estimation.•Geometric mean method with scatter correction, improves accuracy of LSF estimation.•Supported by Monte Carlo, phantom and preliminary patient studies.•Revised methodology facilitates improved accuracy in the dosimetry estimation.•F...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physica medica 2022-07, Vol.99, p.94-101
Hauptverfasser: McArdle, Niamh, Cournane, Seán, McCavana, Jackie, Lucey, Julie, León Vintró, Luis
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Geometric mean method shown to greatly overestimate LSF estimation.•Geometric mean method with scatter correction, improves accuracy of LSF estimation.•Supported by Monte Carlo, phantom and preliminary patient studies.•Revised methodology facilitates improved accuracy in the dosimetry estimation.•Facilitates more optimised prescribed patient therapy dose. Prior to 90Y selective internal radiation therapy (SIRT) treatment, 99mTc-MAA scintigraphy imaging is used in the estimation of the lung shunt fraction (LSF). Planar imaging is recommended for determining a LSF ratio. However, the estimate may be affected by scatter contributions, attenuation and respiratory motion. The objective of this study was to correct for the effects of scatter in the LSF, towards the determination of a more accurate estimation method of LSF derived from planar scintigraphy imaging, which is recommended by international guidelines. The open access SIMIND Monte Carlo modelling software was used to estimate an optimum scatter window (SW) for scatter correction. The uncertainties associated with scatter and scatter contributions from the liver on the LSF were evaluated using an anthropomorphic thorax phantom and a virtual Vox-Man phantom. A brief retrospective examination of patient scans and tumour location investigated the impact that the inclusion of the simulated scatter corrections had on the LSF estimation. The percentage overestimation of the manufacturer recommended method of LSF estimation was 192%. SW corrections improved the uncertainty to within 19% for the range of known LSFs. Similar findings were observed for our patient and tumour location studies. The incorporated scatter corrections can significantly improve the accuracy of the LSF estimation, thereby providing a robust gamma camera, patient and tumour depth specific correction which is easily implementable. This is supported by Monte Carlo, phantom and preliminary patient studies.
ISSN:1120-1797
1724-191X
DOI:10.1016/j.ejmp.2022.05.017