Vortex-assisted liquid-liquid microextraction combined with liquid chromatography tandem mass spectrometry for simultaneous determination of cardiovascular drugs in human plasma
Hypertension and dyslipidemias are among the main risk factors for the development of cardiovascular diseases, which are responsible for the death of approximately 17 million people each year. There are several drugs available for the treatment of these diseases. Therefore, methods for the simultane...
Gespeichert in:
Veröffentlicht in: | Journal of pharmaceutical and biomedical analysis 2022-08, Vol.217, p.114845-114845, Article 114845 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Hypertension and dyslipidemias are among the main risk factors for the development of cardiovascular diseases, which are responsible for the death of approximately 17 million people each year. There are several drugs available for the treatment of these diseases. Therefore, methods for the simultaneous analysis of several of these drugs are useful in a wide range of situations. In this context, this study aimed to develop a modern method for the simultaneous determination of eight cardiovascular drugs in human plasma. A vortex-assisted liquid-liquid microextraction (VALLME) procedure, combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. Mass spectrometry conditions, chromatographic separation, and sample preparation were optimized. For VALLME optimization, pH, sodium chloride concentration, volume of buffer solution, extraction solvent (type and volume), and vortex stirring time were evaluated. The method proved to be simple, fast, and environmentally friendly since low volumes of organic solvent were employed. Furthermore, the VALLME procedure required small sample volume, which is desirable when large volumes are scarce. Suitable recoveries and lower limits of quantification were achieved with a chromatographic run of only 8 min. The method was validated, showing to be selective, precise, and accurate. Furthermore, the analytical curves were well fitted to the selected models and the matrix effect did not affect method reliability. The developed method was successfully applied for the analysis of plasma samples obtained from volunteers attending a hospital service.
[Display omitted]
•A sensitive and selective method was developed to quantify 8 drugs in human plasma.•The method is simple, fast, environmentally friendly, and was fully validated.•Vortex-assisted liquid-liquid microextraction was employed to extract the analytes.•The method needed low sample volumes and achieved low limits of quantification.•The method was successfully applied to quantify 8 drugs in real patient samples. |
---|---|
ISSN: | 0731-7085 1873-264X |
DOI: | 10.1016/j.jpba.2022.114845 |