Roof structural damage of Sitra Power and Water Station phase I multi-stage flash units

Phase I multi-stage flash (MSF) unit roofs have recently experienced major structural damage, especially at the heat reject section. Excessive corrosion of the roof structural supporting beams and plates was not detected at earlier stages because of the thermal insulation material covering the entir...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Desalination 1998-12, Vol.120 (1), p.23-32
Hauptverfasser: Hussain, Moh'd A.Redha Ghulam, Al-Jaziri, A.Hussain Yousif
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Phase I multi-stage flash (MSF) unit roofs have recently experienced major structural damage, especially at the heat reject section. Excessive corrosion of the roof structural supporting beams and plates was not detected at earlier stages because of the thermal insulation material covering the entire roof area of these units. Preliminary investigations revealed that the corrosion of the roof supporting beams and plates was mainly caused by (1) trapping of water (rain and or seawater) between the structure support beams and roof plates causing corrosion of the structural roof beams and hence leading to weak structure and roof partial sagging; (2) trapping of rain water under the insulation material for a prolonged period of time; (3) an overlooked area; and (4) insulation material absorbed the water provided good corrosion cell. Temporary corrective repair work was carried out to bring the unit back into service by welding in new supporting beams. Proper repair work is planned for the station rehabilitation.
ISSN:0011-9164
1873-4464
DOI:10.1016/S0011-9164(98)00198-2