Effects of microsize on the biocompatibility of UiO67 from protein-adsorption behavior, hemocompatibility, and histological toxicity

The biocompatibility of metal–organic frameworks (MOFs) is necessary to humans but is far from being sufficiently addressed. This study focused on the effects of microsize on the biocompatibility of MOFs by selecting UiO67 with micron and submicron size as the MOFs models. Under the dose metric of s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of hazardous materials 2022-08, Vol.435, p.129042-129042, Article 129042
Hauptverfasser: Gan, Na, Peng, Xu, Wu, Di, Xiang, Hongzhao, Sun, Qiaomei, Yi, Bin, Suo, Zili, Zhang, Shuangshuang, Wang, Xinlong, Li, Hui
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The biocompatibility of metal–organic frameworks (MOFs) is necessary to humans but is far from being sufficiently addressed. This study focused on the effects of microsize on the biocompatibility of MOFs by selecting UiO67 with micron and submicron size as the MOFs models. Under the dose metric of surface area, the binding constant between UiO67 and human serum albumin (HSA) gradually increased with increased UiO67 size. Submicron UiO67 induced stronger conformational transformation and more greatly affected the protein surface hydrophobicity than micron UiO67. Micron UiO67 also inhibited the esterase-like activity of HSA through competitive inhibition mechanism, whereas submicron UiO67 inhibited it through noncompetitive inhibition mechanism. The size of UiO67 had little effect on hemocompatibility. A smaller size of UiO67, corresponded with a higher IC50 value for 293 T and LO2 cells, and the adsorption of HSA can effectively improve cytotoxicity. In vivo toxicity evaluations revealed that all UiO67 did not cause obvious distortion of organs, and they were metabolized primarily in the kidney. These results provided useful information about the toxicity of MOFs and experimental references for the development of MOFs-based engineering materials. [Display omitted] •Micron UiO67 had greater binding strength with HSA than submicron UiO67.•Clarify the effect of size on the physicochemical properties of HSA.•Smaller size and HSA binding resulted lower cytotoxicity of UiO67.•Size had no obvious impact on the hemocompatibility and tissue toxicity.•Micron/submicron UiO67 were mainly metabolized in the kidney.
ISSN:0304-3894
1873-3336
DOI:10.1016/j.jhazmat.2022.129042