18F-DOPA PET/CT at the Forefront of Initial or Presurgical Evaluation of Small-Intestine Neuroendocrine Tumors
Our objective was to compare the respective value of 68Ga-DOTATOC and 18F-DOPA PET/CT for initial staging or presurgical work-up of patients with small-intestine neuroendocrine tumors (SiNETs). Methods: This was a retrospective, multicenter, noninterventional investigation involving 53 non–surgicall...
Gespeichert in:
Veröffentlicht in: | J.Nucl.Med 2022-12, Vol.63 (12), p.1865-1870 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Our objective was to compare the respective value of 68Ga-DOTATOC and 18F-DOPA PET/CT for initial staging or presurgical work-up of patients with small-intestine neuroendocrine tumors (SiNETs). Methods: This was a retrospective, multicenter, noninterventional investigation involving 53 non–surgically treated SiNET patients who underwent both 68Ga-DOTATOC and 18F-DOPA PET/CT within a 6-mo interval without surgical intervention or therapeutic change between the 2 PET/CT studies. Percentage detection rate was calculated according to per-region and per-lesion analyses. Sensitivity for primary tumor detection was assessed in 37 surgically treated patients, taking surgical results (76 SiNETs) as the diagnostic gold standard. Results: 68Ga-DOTATOC PET/CT and 18F-DOPA PET/CT individually identified at least 1 primary SiNET in 92% (34/37) of the patients. Intestinal tumor multifocality was confirmed by histology in 8 patients. 68Ga-DOTATOC and 18F-DOPA PET/CT were concordantly positive for tumor multifocality in 5 patients, discordantly positive in 2 patients, and concordantly negative in 1 patient. The detection rate for subdiaphragmatic nodal metastases on per-region–based analysis was 91% and 98% for 68Ga-DOTATOC and 18F-DOPA PET/CT, respectively (P = 0.18). 18F-DOPA PET/CT detected a higher number of abnormal subdiaphragmatic nodes (P = 0.009). Regarding mesenteric nodes only, 18F-DOPA PET/CT detected more positive regions (P = 0.005) and nodal lesions (P = 0.003) than 68Ga-DOTATOC PET/CT, including nodes at the origin of mesenteric vessels. For detection of distant metastases, 68Ga-DOTATOC and 18F-DOPA PET/CT performed equally well on a per-region–based analysis. As compared with 68Ga-DOTATOC, 18F-DOPA PET/CT detected more hepatic (P < 0.001), peritoneal (P < 0.001), and lung metastases (P < 0.001). Conclusion: 18F-DOPA PET/CT detected more lesions than 68Ga-DOTATOC PET/CT in the studied patients. The respective roles of the two should be discussed in terms of disease staging and treatment selection. |
---|---|
ISSN: | 0161-5505 1535-5667 |
DOI: | 10.2967/jnumed.122.263984 |