Implantation of an Impedance Sensor for Early Detection of Gastrointestinal Anastomotic Leaks

Accurate early diagnosis of a gastrointestinal anastomotic leak remains a challenge. When an anastomotic leak develops, the electrical properties of the tissue undergoing inflammatory processes change, resulting from the extravasation of inflammatory fluid and cellular infiltration. The method descr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of surgical research 2022-10, Vol.278, p.49-56
Hauptverfasser: Ben-David, Matan, Carmeli, Idan, Orgad, Ran, Nathansohn-Levi, Bar, Yered, Tal, Shor, Erez, Wasserberg, Nir
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Accurate early diagnosis of a gastrointestinal anastomotic leak remains a challenge. When an anastomotic leak develops, the electrical properties of the tissue undergoing inflammatory processes change, resulting from the extravasation of inflammatory fluid and cellular infiltration. The method described here intends to provide a novel early anastomotic leak warning system based upon measurable changes in tissue impedance nearby an acute inflammatory process. A biodegradable Mg-alloy was compared with a nonabsorbable stainless steel (STS) electrode connected to a wireless recording system for impedance measurement. In vitro measurements were made in physiological solutions and small animal (eight mice) and large animal (eight pigs) models with an anastomotic leak simulated by an open colotomy. Measurements were made at 10 mm intervals from the open colon at baseline and up to 120 min comparing these with a sutured colonic wound and normal tissue. In-vitro biodegradable magnesium electrode impedance evaluation showed good sensitivity to different media due to its environmental corrosion properties. The impedance of an acidic environment (1.06 ± 0.02 kΩ for citric acid) was twice that of phosphate-buffered saline (PBS) (0.64 ± 0.008 kΩ) with a distinction between Normal Saline (0.42 ± 0.013 kΩ) and PBS (0.64 ± 0.008 kΩ). This was in contrast to the performance characteristics of the control STS electrodes, where impedance in an acidic environment was lower than saline or PBS (citric acid:0.76 ± 0.01 kΩ versus PBS: 1.32 ± 0.014 kΩ). In a mouse model simulating an anastomotic leak, there was a significant increase in impedance after 120 min when compared with controls (99.7% increase versus 9.6% increase, respectively; P 
ISSN:0022-4804
1095-8673
DOI:10.1016/j.jss.2022.04.041