New method of internal fixation in laparoscopic Tenckhoff catheter placement
Background Despite obvious advantages of peritoneal dialysis (PD), mechanical complications are responsible for the failure of PD at early stage. Suture fixation in laparoscopic PD catheter method could reduce mechanical complications. In our study, a simple method to fix PD catheter was developed....
Gespeichert in:
Veröffentlicht in: | Seminars in dialysis 2022-11, Vol.35 (6), p.498-503 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Despite obvious advantages of peritoneal dialysis (PD), mechanical complications are responsible for the failure of PD at early stage. Suture fixation in laparoscopic PD catheter method could reduce mechanical complications. In our study, a simple method to fix PD catheter was developed.
Methods
Tenckhoff catheter placement was performed in 49 consecutive patients. In the technique, only two trocars were used. With the help of syringe needle and forceps, a loop of silk was prepared at the abdominal wall. The PD catheter was thread through the loop. The silk ligature was tied subcutaneously keeping the catheter suspended from the abdominal wall. Primary outcomes were catheter‐related complications. Secondary outcomes were 6‐month catheter survival rates and death within 30 days. Data were analyzed retrospectively.
Results
The average operation time was 49.7 ± 15.8 min. Minimum follow‐up time was 6 months. No catheter displacement or hernia was detected. One patient had omental wrapping after silk suture rupture, 2 patients had outflow obstruction, and 3 patients had leakage. No one died within 30 days postoperatively. Catheter survival was 95.8% at 6 months.
Conclusions
The method we described greatly reduced the risk of catheter displacement and omental wrap. Also, the required instrument and laparoscopic skill were simple. |
---|---|
ISSN: | 0894-0959 1525-139X |
DOI: | 10.1111/sdi.13087 |