Integrated opto‐mechanical cantilever sensor with a rib waveguide
An integrated opto‐mechanical cantilever sensor with a rib waveguide is reported in this paper. The device consists of a rib waveguide cantilever with buried waveguides on silicon. The rib cantilever is introduced to match better with the buried waveguide, further for increasing the interface coupli...
Gespeichert in:
Veröffentlicht in: | Journal of microscopy (Oxford) 2022-06, Vol.286 (3), p.240-244 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An integrated opto‐mechanical cantilever sensor with a rib waveguide is reported in this paper. The device consists of a rib waveguide cantilever with buried waveguides on silicon. The rib cantilever is introduced to match better with the buried waveguide, further for increasing the interface coupling efficiency. With this configuration, single‐mode operating can be achieved in transverse direction without decreasing the width of optical waveguide cantilever. The system sensitivity is 1.1 μm–1 which is increased by about 21%, compared with the conventional structure. |
---|---|
ISSN: | 0022-2720 1365-2818 |
DOI: | 10.1111/jmi.13097 |