Value of contrast-enhanced ultrasound for diagnosis and follow-up of renal artery stenosis in patients with chronic kidney disease
Objective To evaluate whether contrast-enhanced ultrasound (CEUS) is an accurate, non-nephrotoxic diagnostic method and follow-up tool for use in patients with chronic kidney disease (CKD) and renal artery stenosis (RAS). Methods In this prospective and monocentric study, we compared the sensitivity...
Gespeichert in:
Veröffentlicht in: | Abdominal imaging 2022-05, Vol.47 (5), p.1853-1861 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective
To evaluate whether contrast-enhanced ultrasound (CEUS) is an accurate, non-nephrotoxic diagnostic method and follow-up tool for use in patients with chronic kidney disease (CKD) and renal artery stenosis (RAS).
Methods
In this prospective and monocentric study, we compared the sensitivity and specificity of CEUS for the diagnosis of RAS in CKD patients, using digital subtraction angiography (DSA) or computed tomographic angiography (CTA) as the gold standard methods. Further, the value of CEUS for distinguishing restenosis from other diseases was assessed. The ultrasound physicians conducted the examinations and served as the CEUS report readers who were blinded to the DSA or CTA results.
Results
Patients with RAS (
n
= 60) were enrolled. Average patient age was 64.4 ± 18.0 years and median estimated glomerular filtration rate was 66.1 mL/min/1.73 m
2
. CEUS was used to image 94 stenotic renal arteries and DSA- or CTA-verified stenosis was present in 96 renal arteries. The kappa value for CEUS was 0.776 (
P
|
---|---|
ISSN: | 2366-0058 2366-004X 2366-0058 |
DOI: | 10.1007/s00261-022-03457-w |