Staged energy and water quality optimization for large water distribution systems

Simultaneous optimization of energy and water quality in real-time large-sized water distribution systems is a daunting task for water suppliers. The complexity of energy optimization increases with a large number of pipes, scheduling of several pumps, and adjustments of tanks’ water levels. Most of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Environmental monitoring and assessment 2022-03, Vol.194 (3), p.232-232, Article 232
Hauptverfasser: Sharif, Muhammad Nadeem, Bakhtavar, Ezzeddin, Haider, Husnain, Hu, Guangji, Hewage, Kasun, Sadiq, Rehan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Simultaneous optimization of energy and water quality in real-time large-sized water distribution systems is a daunting task for water suppliers. The complexity of energy optimization increases with a large number of pipes, scheduling of several pumps, and adjustments of tanks’ water levels. Most of the simultaneous energy and water quality optimization approaches evaluate small (or hypothetical) networks or compromise water quality. In the proposed staged approach, Stage 1 uses a risk-based approach to optimally locate the chlorine boosters in a large distribution system based on residual chlorine failures and the associated consequences in different land uses of the service area. Integrating EPANET and CPLEX software, Stage 2 uses mixed integer goal programming for optimizing the day-ahead pump scheduling. The objective function minimizes the pumping energy cost as well as the undesirable deviations from goal constraints, such as expected water demand. Stage 3 evaluates the combined hydraulics and water quality performances at the network level. The implementation of the proposed approach on a real-time large-sized network of Al-Khobar City in Saudi Arabia, with 44 groundwater wells, 12 reservoirs, 2 storage tanks, 191 mains, 141 junctions, and 17 pumps, illustrated the practicality of the framework. Simulating the network with an optimal pumping schedule and chlorine boosters’ locations shows a 40% improvement in water quality performance, desired hydraulics performance with optimal pump scheduling, and an average 20% energy cost reduction compared to the normal (unoptimized) base case scenario.
ISSN:0167-6369
1573-2959
DOI:10.1007/s10661-022-09874-0