Feasibility of non-invasive neuro-monitoring during extracorporeal membrane oxygenation in children

Introduction Detection of neurological complications during extracorporeal membrane oxygenation (ECMO) may be enhanced with non-invasive neuro-monitoring. We investigated the feasibility of non-invasive neuro-monitoring in a paediatric intensive care (PIC) setting. Methods In a single centre, prospe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Perfusion 2023-04, Vol.38 (3), p.547-556
Hauptverfasser: McDevitt, William M, Farley, Margaret, Martin-Lamb, Darren, Jones, Timothy J, Morris, Kevin P, Seri, Stefano, Scholefield, Barnaby R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction Detection of neurological complications during extracorporeal membrane oxygenation (ECMO) may be enhanced with non-invasive neuro-monitoring. We investigated the feasibility of non-invasive neuro-monitoring in a paediatric intensive care (PIC) setting. Methods In a single centre, prospective cohort study we assessed feasibility of recruitment, and neuro-monitoring via somatosensory evoked potentials (SSEP), electroencephalography (EEG) and near infrared spectroscopy (NIRS) during venoarterial (VA) ECMO in paediatric patients (0–15 years). Measures were obtained within 24h of cannulation, during an intermediate period, and finally at decannulation or echo stress testing. SSEP/EEG/NIRS measures were correlated with neuro-radiology findings, and clinical outcome assessed via the Pediatric cerebral performance category (PCPC) scale 30 days post ECMO cannulation. Results We recruited 14/20 (70%) eligible patients (median age: 9 months; IQR:4–54, 57% male) over an 18-month period, resulting in a total of 42 possible SSEP/EEG/NIRS measurements. Of these, 32/42 (76%) were completed. Missed recordings were due to lack of access/consent within 24 h of cannulation (5/42, 12%) or PIC death/discharge (5/42, 12%). In each patient, the majority of SSEP (8/14, 57%), EEG (8/14, 57%) and NIRS (11/14, 79%) test results were within normal limits. All patients with abnormal neuroradiology (4/10, 40%), and 6/7 (86%) with poor outcome (PCPC ≥4) developed indirect SSEP, EEG or NIRS measures of neurological complications prior to decannulation. No study-related adverse events or neuro-monitoring data interpreting issues were experienced. Conclusion Non-invasive neuro-monitoring (SSEP/EEG/NIRS) during ECMO is feasible and may provide early indication of neurological complications in this high-risk population.
ISSN:0267-6591
1477-111X
DOI:10.1177/02676591211066804