Temperature dependence of hydrogen evolution reaction on nickel oxide electrode in sealed nickel/cadmium cells

The impedance of sealed nickel/cadmium cells around a cell e.m.f. of 0.0 V was measured at five different temperatures between – 10 and +30 °C. The results show that the behaviour is similar at all temperatures. Based on the experimental results, the relation between charge-transfer resistance (R ct...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of power sources 1993-06, Vol.45 (2), p.247-253
Hauptverfasser: Suresh, M.S., Sathyanarayana, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The impedance of sealed nickel/cadmium cells around a cell e.m.f. of 0.0 V was measured at five different temperatures between – 10 and +30 °C. The results show that the behaviour is similar at all temperatures. Based on the experimental results, the relation between charge-transfer resistance (R ct) and temperature ( T) has been established for the Volmer reaction. Further, the value of cathodic transfer coefficient (α) has been estimated.
ISSN:0378-7753
1873-2755
DOI:10.1016/0378-7753(93)87015-U