Test–Retest Reproducibility of In Vivo Magnetization Transfer Ratio and Saturation Index in Mice at 9.4 Tesla
Background Magnetization transfer saturation (MTsat) imaging was developed to reduce T1 dependence and improve specificity to myelin, compared to the widely used MT ratio (MTR) approach, while maintaining a feasible scan time. As MTsat imaging is an emerging technique, the reproducibility of MTsat c...
Gespeichert in:
Veröffentlicht in: | Journal of magnetic resonance imaging 2022-09, Vol.56 (3), p.893-903 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Magnetization transfer saturation (MTsat) imaging was developed to reduce T1 dependence and improve specificity to myelin, compared to the widely used MT ratio (MTR) approach, while maintaining a feasible scan time. As MTsat imaging is an emerging technique, the reproducibility of MTsat compared to MTR must be evaluated.
Purpose
To assess the test–retest reproducibility of MTR and MTsat in the mouse brain at 9.4 T and calculate sample sizes potentially required to detect effect sizes ranging from 6% to 14%.
Study Type
Prospective.
Subjects
Twelve healthy C57Bl/6 mice.
Field Strength/Sequence
9.4 T; magnetization transfer imaging using FLASH‐3D Gradient Echo; T2‐weighted TurboRARE spin echo.
Assessment
All mice were scanned at two timepoints (5 days apart). MTR and MTsat maps were analyzed using mean region‐of‐interest (ROIs: corpus callosum [CC], internal capsule [IC], hippocampus [HC], cortex [CX], and thalamus [TH]), and whole brain voxel‐wise analysis.
Statistical Tests
Bland–Altman plots were used to assess biases between test–retest measurements. Test–retest reproducibility was evaluated via between and within‐subject coefficients of variation (bsCV and wsCV, respectively). Sample sizes required were calculated (significance level: 95%; power: 80%), given effect sizes ranging from 6% to 14%, using both between and within‐subject approaches. Results were considered statistically significant at P ≤ 0.05.
Results
Bland–Altman plots showed negligible biases between test–retest sessions (MTR: 0.0009; MTsat: 0). ROI‐based and voxel‐wise CVs revealed high reproducibility for both MTR (ROI‐bsCV/wsCV: CC—4.5/2.8%; IC—6.1/5.2%; HC—5.7/4.6%; CX—5.1/2.3%; TH—7.4/4.9%) and MTsat (ROI‐bsCV/wsCV: CC—6.3/4.8%; IC—7.3/5.1%; HC—9.5/6.4%; CX—6.7/6.5%; TH—7.2/5.3%). With a sample size of 6, changes on the order of 15% could be detected in MTR and MTsat, both between and within subjects, while smaller changes (6%–8%) required sample sizes of 10–15 for MTR, and 15–20 for MTsat.
Data Conclusion
MTsat exhibited comparable reproducibility to MTR, while providing sensitivity to myelin with less T1 dependence than MTR.
Evidence Level
2
Technical Efficacy
Stage 1 |
---|---|
ISSN: | 1053-1807 1522-2586 |
DOI: | 10.1002/jmri.28106 |