Comparison of fit accuracy between conventional and CAD/CAM‐fabricated band–loop space maintainers
Aim The aim of this in vitro study was to evaluate the band fit of metallic band–loop space maintainers fabricated by conventional and 3D printing technologies for clinical applications. Design Sixteen digital intraoral impressions were selected, and resin models were printed with a 3D printer. Fort...
Gespeichert in:
Veröffentlicht in: | International journal of paediatric dentistry 2022-09, Vol.32 (5), p.764-771 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Aim
The aim of this in vitro study was to evaluate the band fit of metallic band–loop space maintainers fabricated by conventional and 3D printing technologies for clinical applications.
Design
Sixteen digital intraoral impressions were selected, and resin models were printed with a 3D printer. Forty band–loop space maintainers were fabricated (20 each for both the conventional and digital groups). To evaluate the band fit of conventional and CAD/CAM‐fabricated space maintainers, cement space was visualized with low‐viscosity condensation silicone material on resin models. Digital evaluation was carried out using dual scan method by superimposing two scans of resin models covered with or without a silicone layer on the abutment tooth. The mean quadratic deviation (root mean square, RMS) was calculated. The RMS values between the groups were evaluated with Student's t test. Statistical significance was set at p |
---|---|