Diagnostic reference level for adult pelvic examination in several hospitals of Taif and Kharaj city, Saudi Arabia

The current study was aimed to estimate the entrance surface air kerma (ESAK, mGy) for adult patients undergoing conventional radiography of Anteroposterior pelvis examination, and finally to establish a local diagnostic reference level (DRL). A total of 500 patients were exposed to diagnostic radia...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 2022-02, Vol.180, p.110049-110049, Article 110049
Hauptverfasser: Osman, Hamid, Raafat, Bassem M., Faizo, Nahla L., Ahmed, Rania Mohammed, Alamri, Sultan, Alghamdi, Ahmad Joman, Almahwasi, Ashraf, Alharbi, M.K.M., Sulieman, A., Khandaker, Mayeen Uddin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 110049
container_issue
container_start_page 110049
container_title Applied radiation and isotopes
container_volume 180
creator Osman, Hamid
Raafat, Bassem M.
Faizo, Nahla L.
Ahmed, Rania Mohammed
Alamri, Sultan
Alghamdi, Ahmad Joman
Almahwasi, Ashraf
Alharbi, M.K.M.
Sulieman, A.
Khandaker, Mayeen Uddin
description The current study was aimed to estimate the entrance surface air kerma (ESAK, mGy) for adult patients undergoing conventional radiography of Anteroposterior pelvis examination, and finally to establish a local diagnostic reference level (DRL). A total of 500 patients were exposed to diagnostic radiation in four hospitals (coded A, B, C, and D) in Taif and Kharaj city, Saudi Arabia, with different X-ray equipment specifications. Patient demographic data like age (y), body mass index (BMI) in kg/m2 as well as exposure factors and X-ray tube output were recorded. ESAK (mGy) was first calculated using the exposure data and tube output values, then the ESAK values were used to estimate entrance surface dose (ESD). The average BMI was 23.9 kg/m2. The mean tube potential used in A, B, C, and D hospitals and the corresponding estimated ESD were found to be 74.2, 69.8, 73, 76,7 kVp, and 2.54, 2.64, 2.94, 3.03 mGy respectively. The correlation coefficient between ESAK and BMI was found to be 0.98. When compared to computed radiography (CR), the conventional X-ray digital radiography reduces the radiation exposure in pelvic imaging by a factor of 1.18. The third quartile of median proposed a lower than the DRL of the previous studies. •Entrance skin air kerma and dose were determined for patients underwent pelvis examination.•Correlation coefficient found to be 0.98 between ESAK and body mass index values.•Digital radiography reduces the radiation exposure by a factor of 1.18 than the CT.•Third quartile of ESAK values used to determine DRL and found to be lower than the literature.
doi_str_mv 10.1016/j.apradiso.2021.110049
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2607304284</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969804321004413</els_id><sourcerecordid>2607304284</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-71537f349303814e02fa26ef0fb85781acf43ff1110c1625977c5f5c2a89ce6c3</originalsourceid><addsrcrecordid>eNqFkEtP3DAUhS1UBAPtX0BesmgGv-I4uyLeAqmL0rV1x7kuHmXiYCcj-Pf1aKDbru7mO_fofISccbbkjOuL9RLGBF3IcSmY4EvOGVPtAVlw04iqNYx9IQvW6rYyTMljcpLzmhXEtOKIHEtltFKyWZB0HeDPEPMUHE3oMeHgkPa4xZ76mCh0cz_REfttAfANNmGAKcSBhoHmQiXo6UvMY5igzzR6-gzBUxg6-vgCCdbUhen9O_0FcxfoZYJVgK_k0BcYv33cU_L79ub56r56-nn3cHX5VDmpzVQ1vJaNl6qVTBqukAkPQqNnfmXqxnBwXknveVnuuBZ12zSu9rUTYFqH2slTcr7_O6b4OmOe7CZkh30PA8Y5W6FZI5kSRhVU71GXYs7Fgx1T2EB6t5zZnW-7tp--7c633fsuwbOPjnm1we5f7FNwAX7sASxLtwGTzS7sHHchoZtsF8P_Ov4C4smU8w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2607304284</pqid></control><display><type>article</type><title>Diagnostic reference level for adult pelvic examination in several hospitals of Taif and Kharaj city, Saudi Arabia</title><source>Elsevier ScienceDirect Journals</source><creator>Osman, Hamid ; Raafat, Bassem M. ; Faizo, Nahla L. ; Ahmed, Rania Mohammed ; Alamri, Sultan ; Alghamdi, Ahmad Joman ; Almahwasi, Ashraf ; Alharbi, M.K.M. ; Sulieman, A. ; Khandaker, Mayeen Uddin</creator><creatorcontrib>Osman, Hamid ; Raafat, Bassem M. ; Faizo, Nahla L. ; Ahmed, Rania Mohammed ; Alamri, Sultan ; Alghamdi, Ahmad Joman ; Almahwasi, Ashraf ; Alharbi, M.K.M. ; Sulieman, A. ; Khandaker, Mayeen Uddin</creatorcontrib><description>The current study was aimed to estimate the entrance surface air kerma (ESAK, mGy) for adult patients undergoing conventional radiography of Anteroposterior pelvis examination, and finally to establish a local diagnostic reference level (DRL). A total of 500 patients were exposed to diagnostic radiation in four hospitals (coded A, B, C, and D) in Taif and Kharaj city, Saudi Arabia, with different X-ray equipment specifications. Patient demographic data like age (y), body mass index (BMI) in kg/m2 as well as exposure factors and X-ray tube output were recorded. ESAK (mGy) was first calculated using the exposure data and tube output values, then the ESAK values were used to estimate entrance surface dose (ESD). The average BMI was 23.9 kg/m2. The mean tube potential used in A, B, C, and D hospitals and the corresponding estimated ESD were found to be 74.2, 69.8, 73, 76,7 kVp, and 2.54, 2.64, 2.94, 3.03 mGy respectively. The correlation coefficient between ESAK and BMI was found to be 0.98. When compared to computed radiography (CR), the conventional X-ray digital radiography reduces the radiation exposure in pelvic imaging by a factor of 1.18. The third quartile of median proposed a lower than the DRL of the previous studies. •Entrance skin air kerma and dose were determined for patients underwent pelvis examination.•Correlation coefficient found to be 0.98 between ESAK and body mass index values.•Digital radiography reduces the radiation exposure by a factor of 1.18 than the CT.•Third quartile of ESAK values used to determine DRL and found to be lower than the literature.</description><identifier>ISSN: 0969-8043</identifier><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/j.apradiso.2021.110049</identifier><identifier>PMID: 34864437</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>ESAK ; Medical imaging ; Pelvis ; Radiology ; X-ray</subject><ispartof>Applied radiation and isotopes, 2022-02, Vol.180, p.110049-110049, Article 110049</ispartof><rights>2021 Elsevier Ltd</rights><rights>Copyright © 2021 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-71537f349303814e02fa26ef0fb85781acf43ff1110c1625977c5f5c2a89ce6c3</citedby><cites>FETCH-LOGICAL-c368t-71537f349303814e02fa26ef0fb85781acf43ff1110c1625977c5f5c2a89ce6c3</cites><orcidid>0000-0001-5370-7358 ; 0000-0003-4536-8231 ; 0000-0002-8285-6915 ; 0000-0003-3772-294X ; 0000-0003-4612-8811</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.apradiso.2021.110049$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,45974</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34864437$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Osman, Hamid</creatorcontrib><creatorcontrib>Raafat, Bassem M.</creatorcontrib><creatorcontrib>Faizo, Nahla L.</creatorcontrib><creatorcontrib>Ahmed, Rania Mohammed</creatorcontrib><creatorcontrib>Alamri, Sultan</creatorcontrib><creatorcontrib>Alghamdi, Ahmad Joman</creatorcontrib><creatorcontrib>Almahwasi, Ashraf</creatorcontrib><creatorcontrib>Alharbi, M.K.M.</creatorcontrib><creatorcontrib>Sulieman, A.</creatorcontrib><creatorcontrib>Khandaker, Mayeen Uddin</creatorcontrib><title>Diagnostic reference level for adult pelvic examination in several hospitals of Taif and Kharaj city, Saudi Arabia</title><title>Applied radiation and isotopes</title><addtitle>Appl Radiat Isot</addtitle><description>The current study was aimed to estimate the entrance surface air kerma (ESAK, mGy) for adult patients undergoing conventional radiography of Anteroposterior pelvis examination, and finally to establish a local diagnostic reference level (DRL). A total of 500 patients were exposed to diagnostic radiation in four hospitals (coded A, B, C, and D) in Taif and Kharaj city, Saudi Arabia, with different X-ray equipment specifications. Patient demographic data like age (y), body mass index (BMI) in kg/m2 as well as exposure factors and X-ray tube output were recorded. ESAK (mGy) was first calculated using the exposure data and tube output values, then the ESAK values were used to estimate entrance surface dose (ESD). The average BMI was 23.9 kg/m2. The mean tube potential used in A, B, C, and D hospitals and the corresponding estimated ESD were found to be 74.2, 69.8, 73, 76,7 kVp, and 2.54, 2.64, 2.94, 3.03 mGy respectively. The correlation coefficient between ESAK and BMI was found to be 0.98. When compared to computed radiography (CR), the conventional X-ray digital radiography reduces the radiation exposure in pelvic imaging by a factor of 1.18. The third quartile of median proposed a lower than the DRL of the previous studies. •Entrance skin air kerma and dose were determined for patients underwent pelvis examination.•Correlation coefficient found to be 0.98 between ESAK and body mass index values.•Digital radiography reduces the radiation exposure by a factor of 1.18 than the CT.•Third quartile of ESAK values used to determine DRL and found to be lower than the literature.</description><subject>ESAK</subject><subject>Medical imaging</subject><subject>Pelvis</subject><subject>Radiology</subject><subject>X-ray</subject><issn>0969-8043</issn><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNqFkEtP3DAUhS1UBAPtX0BesmgGv-I4uyLeAqmL0rV1x7kuHmXiYCcj-Pf1aKDbru7mO_fofISccbbkjOuL9RLGBF3IcSmY4EvOGVPtAVlw04iqNYx9IQvW6rYyTMljcpLzmhXEtOKIHEtltFKyWZB0HeDPEPMUHE3oMeHgkPa4xZ76mCh0cz_REfttAfANNmGAKcSBhoHmQiXo6UvMY5igzzR6-gzBUxg6-vgCCdbUhen9O_0FcxfoZYJVgK_k0BcYv33cU_L79ub56r56-nn3cHX5VDmpzVQ1vJaNl6qVTBqukAkPQqNnfmXqxnBwXknveVnuuBZ12zSu9rUTYFqH2slTcr7_O6b4OmOe7CZkh30PA8Y5W6FZI5kSRhVU71GXYs7Fgx1T2EB6t5zZnW-7tp--7c633fsuwbOPjnm1we5f7FNwAX7sASxLtwGTzS7sHHchoZtsF8P_Ov4C4smU8w</recordid><startdate>202202</startdate><enddate>202202</enddate><creator>Osman, Hamid</creator><creator>Raafat, Bassem M.</creator><creator>Faizo, Nahla L.</creator><creator>Ahmed, Rania Mohammed</creator><creator>Alamri, Sultan</creator><creator>Alghamdi, Ahmad Joman</creator><creator>Almahwasi, Ashraf</creator><creator>Alharbi, M.K.M.</creator><creator>Sulieman, A.</creator><creator>Khandaker, Mayeen Uddin</creator><general>Elsevier Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-5370-7358</orcidid><orcidid>https://orcid.org/0000-0003-4536-8231</orcidid><orcidid>https://orcid.org/0000-0002-8285-6915</orcidid><orcidid>https://orcid.org/0000-0003-3772-294X</orcidid><orcidid>https://orcid.org/0000-0003-4612-8811</orcidid></search><sort><creationdate>202202</creationdate><title>Diagnostic reference level for adult pelvic examination in several hospitals of Taif and Kharaj city, Saudi Arabia</title><author>Osman, Hamid ; Raafat, Bassem M. ; Faizo, Nahla L. ; Ahmed, Rania Mohammed ; Alamri, Sultan ; Alghamdi, Ahmad Joman ; Almahwasi, Ashraf ; Alharbi, M.K.M. ; Sulieman, A. ; Khandaker, Mayeen Uddin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-71537f349303814e02fa26ef0fb85781acf43ff1110c1625977c5f5c2a89ce6c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>ESAK</topic><topic>Medical imaging</topic><topic>Pelvis</topic><topic>Radiology</topic><topic>X-ray</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Osman, Hamid</creatorcontrib><creatorcontrib>Raafat, Bassem M.</creatorcontrib><creatorcontrib>Faizo, Nahla L.</creatorcontrib><creatorcontrib>Ahmed, Rania Mohammed</creatorcontrib><creatorcontrib>Alamri, Sultan</creatorcontrib><creatorcontrib>Alghamdi, Ahmad Joman</creatorcontrib><creatorcontrib>Almahwasi, Ashraf</creatorcontrib><creatorcontrib>Alharbi, M.K.M.</creatorcontrib><creatorcontrib>Sulieman, A.</creatorcontrib><creatorcontrib>Khandaker, Mayeen Uddin</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Osman, Hamid</au><au>Raafat, Bassem M.</au><au>Faizo, Nahla L.</au><au>Ahmed, Rania Mohammed</au><au>Alamri, Sultan</au><au>Alghamdi, Ahmad Joman</au><au>Almahwasi, Ashraf</au><au>Alharbi, M.K.M.</au><au>Sulieman, A.</au><au>Khandaker, Mayeen Uddin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Diagnostic reference level for adult pelvic examination in several hospitals of Taif and Kharaj city, Saudi Arabia</atitle><jtitle>Applied radiation and isotopes</jtitle><addtitle>Appl Radiat Isot</addtitle><date>2022-02</date><risdate>2022</risdate><volume>180</volume><spage>110049</spage><epage>110049</epage><pages>110049-110049</pages><artnum>110049</artnum><issn>0969-8043</issn><eissn>1872-9800</eissn><abstract>The current study was aimed to estimate the entrance surface air kerma (ESAK, mGy) for adult patients undergoing conventional radiography of Anteroposterior pelvis examination, and finally to establish a local diagnostic reference level (DRL). A total of 500 patients were exposed to diagnostic radiation in four hospitals (coded A, B, C, and D) in Taif and Kharaj city, Saudi Arabia, with different X-ray equipment specifications. Patient demographic data like age (y), body mass index (BMI) in kg/m2 as well as exposure factors and X-ray tube output were recorded. ESAK (mGy) was first calculated using the exposure data and tube output values, then the ESAK values were used to estimate entrance surface dose (ESD). The average BMI was 23.9 kg/m2. The mean tube potential used in A, B, C, and D hospitals and the corresponding estimated ESD were found to be 74.2, 69.8, 73, 76,7 kVp, and 2.54, 2.64, 2.94, 3.03 mGy respectively. The correlation coefficient between ESAK and BMI was found to be 0.98. When compared to computed radiography (CR), the conventional X-ray digital radiography reduces the radiation exposure in pelvic imaging by a factor of 1.18. The third quartile of median proposed a lower than the DRL of the previous studies. •Entrance skin air kerma and dose were determined for patients underwent pelvis examination.•Correlation coefficient found to be 0.98 between ESAK and body mass index values.•Digital radiography reduces the radiation exposure by a factor of 1.18 than the CT.•Third quartile of ESAK values used to determine DRL and found to be lower than the literature.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>34864437</pmid><doi>10.1016/j.apradiso.2021.110049</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0001-5370-7358</orcidid><orcidid>https://orcid.org/0000-0003-4536-8231</orcidid><orcidid>https://orcid.org/0000-0002-8285-6915</orcidid><orcidid>https://orcid.org/0000-0003-3772-294X</orcidid><orcidid>https://orcid.org/0000-0003-4612-8811</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0969-8043
ispartof Applied radiation and isotopes, 2022-02, Vol.180, p.110049-110049, Article 110049
issn 0969-8043
1872-9800
language eng
recordid cdi_proquest_miscellaneous_2607304284
source Elsevier ScienceDirect Journals
subjects ESAK
Medical imaging
Pelvis
Radiology
X-ray
title Diagnostic reference level for adult pelvic examination in several hospitals of Taif and Kharaj city, Saudi Arabia
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T03%3A59%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Diagnostic%20reference%20level%20for%20adult%20pelvic%20examination%20in%20several%20hospitals%20of%20Taif%20and%20Kharaj%20city,%20Saudi%20Arabia&rft.jtitle=Applied%20radiation%20and%20isotopes&rft.au=Osman,%20Hamid&rft.date=2022-02&rft.volume=180&rft.spage=110049&rft.epage=110049&rft.pages=110049-110049&rft.artnum=110049&rft.issn=0969-8043&rft.eissn=1872-9800&rft_id=info:doi/10.1016/j.apradiso.2021.110049&rft_dat=%3Cproquest_cross%3E2607304284%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2607304284&rft_id=info:pmid/34864437&rft_els_id=S0969804321004413&rfr_iscdi=true