Single-centre experience with endovascular rotational thrombectomy for single session salvage of thrombosed arteriovenous fistulas and grafts

Objectives: This paper documents our experience and outcomes of using a relatively new endovascular rotational thrombectomy device for salvage of thrombosed vascular access. Methodology: A retrospective study reviewing patients with thrombosed native AVF or AVG who underwent endovascular declotting...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The journal of vascular access 2023-09, Vol.24 (5), p.965-971
Hauptverfasser: Lim, Cheryl, Kwan, Justin, Lo, Zhiwen Joseph, Hong, Qiantai, Zhang, Li, Chong, Lester, Huang, Ivan Kuang Hsin, Lim, Gavin Hock Tai, Quek, Lawrence Han Hwee, Pua, Uei, Punamiya, Sundeep, Chandrasekar, Sadhana, Tan, Glenn Wei Leong, Yong, Enming
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives: This paper documents our experience and outcomes of using a relatively new endovascular rotational thrombectomy device for salvage of thrombosed vascular access. Methodology: A retrospective study reviewing patients with thrombosed native AVF or AVG who underwent endovascular declotting using a rotational thrombectomy device between November 2018 and May 2020 at a tertiary university hospital in Southeast Asia. We evaluated demographics, procedural data, technical and procedural success, patency rates and complications. Results: A total of 40 patients underwent single session endovascular declotting of thrombosed vascular access. The mean follow-up period was 21.6 months (range 13.4–31 months). The technical success was 92.5% and clinical success was 80%. About 50% of patients had concomitant thrombolysis for pharmacomechanical thrombectomy. One patient had a myocardial infarction during the post-operative period. There were no other major complications within 30 days. The primary patency was 45.5% at 6 months and 22.7% at 12 months. Assisted primary patency was 68.1% at 6 months and 61.6% at 12 months, which was maintained up to 2 years. The secondary patency was 84.1% at 6 and 12 months. Conclusion: Our study shows that rotational thrombectomy device for single session thrombectomy of thrombosed arteriovenous fistulas and grafts is safe and effective. A high technical and clinical success rate was achieved, with low complication rates and specific advantages compared to other techniques, including reduced length of hospital stay. Our reported mid-term outcomes are reasonable with an assisted primary patency of 62% at 12 and 24 months. The use of newer techniques and novel dedicated thrombectomy devices show promise.
ISSN:1129-7298
1724-6032
DOI:10.1177/11297298211060964