Horizontal stent deployment via extracranial-intracranial bypass in coil embolization of basilar apex aneurysms: technical report
Background The endovascular treatment of large, wide-necked basilar apex aneurysms (BAAs) remains challenging. Although horizontal stent deployment across both P1 segments of the posterior cerebral arteries (PCAs) would be an optimal strategy in coil embolization of wide-necked BAAs, this is only fe...
Gespeichert in:
Veröffentlicht in: | Acta neurochirurgica 2022-05, Vol.164 (5), p.1281-1285 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
The endovascular treatment of large, wide-necked basilar apex aneurysms (BAAs) remains challenging. Although horizontal stent deployment across both P1 segments of the posterior cerebral arteries (PCAs) would be an optimal strategy in coil embolization of wide-necked BAAs, this is only feasible in cases with anatomically favorable access. In rare circumstances, large-diameter conduits of extracranial-intracranial (EC-IC) bypass can also provide a good access route for endovascular treatment of complex intracranial aneurysms.
Methods
We describe the technique of accessing the PCA via EC-IC bypass grafts and deploying a stent horizontally across the neck of BAA and its coil embolization. We provide a detailed technical review and describe some pitfalls of the procedure.
Results
Two patients underwent EC-IC bypass surgery prior to the treatment of a large, wide-necked BAA. The radial artery and saphenous vein were used as grafts, respectively. To facilitate coil embolization for a large BAA, a PCA-to-PCA horizontal stent was deployed via the bypass graft. Trans-cell and jailing techniques were used, respectively. Both aneurysms were completely occluded, and the patients were discharged without any neurological deficit.
Conclusion
Horizontal stent deployment via EC-IC bypass grafts can be performed safely, providing proper closure of the aneurysmal neck and apposition to both PCAs, facilitating complete coil embolization. |
---|---|
ISSN: | 0942-0940 0001-6268 0942-0940 |
DOI: | 10.1007/s00701-021-05070-0 |