Performance of hybrid moment-resisting precast beam-column concrete connections subjected to cyclic loading
Test results of 10 hybrid precast concrete beam-to-column connections are presented. These tests constitute Phase IV of an experimental program on one-third-scale model precast moment-resisting connections conducted at the National Institute of Standards and Technology (NIST). The objective of the t...
Gespeichert in:
Veröffentlicht in: | ACI structural journal 1995-03, Vol.92 (2), p.229-249 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Test results of 10 hybrid precast concrete beam-to-column connections are presented. These tests constitute Phase IV of an experimental program on one-third-scale model precast moment-resisting connections conducted at the National Institute of Standards and Technology (NIST). The objective of the test program is to develop guidelines for the design of moment-resisting precast connections in regions of high seismicity. The hybrid connections consist of mild steel used to dissipate energy and post-tensioning (PT) steel used to provide the required shear resistance. Variables examined were the amount and type of mild steel (ASTM A 615). The amount of post-tensioning steel was varied to control the relative moment capacity contributed by the PT and mild steel. The specimens were subjected to reversed cyclic loading in accordance with a prescribed displacement history. Connection performances were compared to previous NIST tests based on energy dissipation capacity, connection strength, and drift capacity. |
---|---|
ISSN: | 0889-3241 1944-7361 |
DOI: | 10.14359/1145 |