Dynamic 13 C MR spectroscopy as an alternative to imaging for assessing cerebral metabolism using hyperpolarized pyruvate in humans
This study is to investigate time-resolved C MR spectroscopy (MRS) as an alternative to imaging for assessing pyruvate metabolism using hyperpolarized (HP) [1- C]pyruvate in the human brain. Time-resolved C spectra were acquired from four axial brain slices of healthy human participants (n = 4) afte...
Gespeichert in:
Veröffentlicht in: | Magnetic resonance in medicine 2022-03, Vol.87 (3), p.1136-1149 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study is to investigate time-resolved
C MR spectroscopy (MRS) as an alternative to imaging for assessing pyruvate metabolism using hyperpolarized (HP) [1-
C]pyruvate in the human brain.
Time-resolved
C spectra were acquired from four axial brain slices of healthy human participants (n = 4) after a bolus injection of HP [1-
C]pyruvate.
C MRS with low flip-angle excitations and a multichannel
C/
H dual-frequency radiofrequency (RF) coil were exploited for reliable and unperturbed assessment of HP pyruvate metabolism. Slice-wise areas under the curve (AUCs) of
C-metabolites were measured and kinetic analysis was performed to estimate the production rates of lactate and
. Linear regression analysis between brain volumes and HP signals was performed. Region-focused pyruvate metabolism was estimated using coil-wise
C reconstruction. Reproducibility of HP pyruvate exams was presented by performing two consecutive injections with a 45-minutes interval.
[1-
C]Lactate relative to the total
C signal (tC) was 0.21-0.24 in all slices. [
C]
/tC was 0.065-0.091. Apparent conversion rate constants from pyruvate to lactate and
were calculated as 0.014-0.018 s
and 0.0043-0.0056 s
, respectively. Pyruvate/tC and lactate/tC were in moderate linear relationships with fractional gray matter volume within each slice. White matter presented poor linear regression fit with HP signals, and moderate correlations of the fractional cerebrospinal fluid volume with pyruvate/tC and lactate/tC were measured. Measured HP signals were comparable between two consecutive exams with HP [1-
C]pyruvate.
Dynamic MRS in combination with multichannel RF coils is an affordable and reliable alternative to imaging methods in investigating cerebral metabolism using HP [1-
C]pyruvate. |
---|---|
ISSN: | 0740-3194 1522-2594 |
DOI: | 10.1002/mrm.29049 |