Interlaboratory Analytical Validation of a Next-Generation Sequencing Strategy for Clonotypic Assessment and Minimal Residual Disease Monitoring in Multiple Myeloma

Minimal residual disease (MRD) is a major prognostic factor in multiple myeloma, although validated technologies are limited. To standardize the performance of the LymphoTrack next-generation sequencing (NGS) assays (Invivoscribe), targeting clonal immunoglobulin rearrangements, in order to reproduc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of pathology & laboratory medicine (1976) 2022-07, Vol.146 (7), p.862-871
Hauptverfasser: Medina, Alejandro, Jiménez, Cristina, Puig, Noemí, Sarasquete, María Eugenia, Flores-Montero, Juan, García-Álvarez, María, Prieto-Conde, Isabel, Chillón, Carmen, Alcoceba, Miguel, González-Calle, Verónica, Gutiérrez, Norma C, Jacobsen, Austin, Vigil, Edgar, Hutt, Kasey, Huang, Ying, Orfao, Alberto, González, Marcos, Miller, Jeffrey, García-Sanz, Ramón
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Minimal residual disease (MRD) is a major prognostic factor in multiple myeloma, although validated technologies are limited. To standardize the performance of the LymphoTrack next-generation sequencing (NGS) assays (Invivoscribe), targeting clonal immunoglobulin rearrangements, in order to reproduce the detection of tumor clonotypes and MRD quantitation in myeloma. The quantification ability of the assay was evaluated through serial dilution experiments. Paired samples from 101 patients were tested by LymphoTrack, using Sanger sequencing and EuroFlow's next-generation flow (NGF) assay as validated references for diagnostic and follow-up evaluation, respectively. MRD studies using LymphoTrack were performed in parallel at 2 laboratories to evaluate reproducibility. Sensitivity was set as 1.3 tumor cells per total number of input cells. Clonality was confirmed in 99% and 100% of cases with Sanger and NGS, respectively, showing great concordance (97.9%), although several samples had minor discordances in the nucleotide sequence of rearrangements. Parallel NGS was performed in 82 follow-up cases, achieving a median sensitivity of 0.001%, while for NGF, median sensitivity was 0.0002%. Reproducibility of LymphoTrack-based MRD studies (85.4%) and correlation with NGF (R2 > 0.800) were high. Bland-Altman tests showed highly significant levels of agreement between flow and sequencing. Taken together, we have shown that LymphoTrack is a suitable strategy for clonality detection and MRD evaluation, with results comparable to gold standard procedures.
ISSN:0003-9985
1543-2165
1543-2165
DOI:10.5858/arpa.2021-0088-OA