Natural Language Mapping of Electrocardiogram Interpretations to a Standardized Ontology

Abstract Background  Interpretations of the electrocardiogram (ECG) are often prepared using software outside the electronic health record (EHR) and imported via an interface as a narrative note. Thus, natural language processing is required to create a computable representation of the findings. Cha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Methods of information in medicine 2021-09, Vol.60 (3/04), p.104-109
Hauptverfasser: Epstein, Richard H., Jean, Yuel-Kai, Dudaryk, Roman, Freundlich, Robert E., Walco, Jeremy P., Mueller, Dorothee A., Banks, Shawn E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background  Interpretations of the electrocardiogram (ECG) are often prepared using software outside the electronic health record (EHR) and imported via an interface as a narrative note. Thus, natural language processing is required to create a computable representation of the findings. Challenges include misspellings, nonstandard abbreviations, jargon, and equivocation in diagnostic interpretations. Objectives  Our objective was to develop an algorithm to reliably and efficiently extract such information and map it to the standardized ECG ontology developed jointly by the American Heart Association, the American College of Cardiology Foundation, and the Heart Rhythm Society. The algorithm was to be designed to be easily modifiable for use with EHRs and ECG reporting systems other than the ones studied. Methods  An algorithm using natural language processing techniques was developed in structured query language to extract and map quantitative and diagnostic information from ECG narrative reports to the cardiology societies' standardized ECG ontology. The algorithm was developed using a training dataset of 43,861 ECG reports and applied to a test dataset of 46,873 reports. Results  Accuracy, precision, recall, and the F1-measure were all 100% in the test dataset for the extraction of quantitative data (e.g., PR and QTc interval, atrial and ventricular heart rate). Performances for matches in each diagnostic category in the standardized ECG ontology were all above 99% in the test dataset. The processing speed was approximately 20,000 reports per minute. We externally validated the algorithm from another institution that used a different ECG reporting system and found similar performance. Conclusion  The developed algorithm had high performance for creating a computable representation of ECG interpretations. Software and lookup tables are provided that can easily be modified for local customization and for use with other EHR and ECG reporting systems. This algorithm has utility for research and in clinical decision-support where incorporation of ECG findings is desired.
ISSN:0026-1270
2511-705X
2511-705X
DOI:10.1055/s-0041-1736312