Testing meshes in a computer model of a laparoscopic ventral hernia repair
Background The ideal mesh for hernia repair has yet to be found, in addition our knowledge of the biomechanics of the abdominal wall is poor. The aim of this study was to develop a computer model of a laparoscopic ventral hernia repair and to test different meshes in that model at various intra-abdo...
Gespeichert in:
Veröffentlicht in: | Surgical endoscopy 2022-06, Vol.36 (6), p.4124-4128 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
The ideal mesh for hernia repair has yet to be found, in addition our knowledge of the biomechanics of the abdominal wall is poor. The aim of this study was to develop a computer model of a laparoscopic ventral hernia repair and to test different meshes in that model at various intra-abdominal pressures.
Methods
Four meshes were tested in a computer model of a ventral hernia. Mechanical failure testing of each mesh was performed in both the longitudinal and transverse directions. A CT scan of a patient with a 5 cm umbilical hernia was used to generate a 3 dimensional model. Meshes were then applied to the model in an intraperitoneal onlay position with a 5 cm overlap. The model was then tested with intraabdominal pressures for standing, coughing and jumping with and without meshes.
Results
Meshes varied significantly (
p
|
---|---|
ISSN: | 0930-2794 1432-2218 |