Effective fluoride removal from brackish groundwaters by flow-electrode capacitive deionization (FCDI) under a continuous-flow mode

Herein, we demonstrated the suitability and effectiveness of utilizing flow-electrode capacitive deionization (FCDI) for treatment of fluoride-contaminated brackish groundwater. By comparing operational modes of short-circuited closed-cycle (SCC), isolated closed-cycle (ICC) and single cycle (SC), i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Science of the total environment 2022-01, Vol.804, p.150166-150166, Article 150166
Hauptverfasser: Jiang, Huan, Zhang, Jing, Luo, Kunyue, Xing, Wenle, Du, Jiaxin, Dong, Yi, Li, Xiaoting, Tang, Wangwang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Herein, we demonstrated the suitability and effectiveness of utilizing flow-electrode capacitive deionization (FCDI) for treatment of fluoride-contaminated brackish groundwater. By comparing operational modes of short-circuited closed-cycle (SCC), isolated closed-cycle (ICC) and single cycle (SC), it was found that SCC mode was the most advantageous. In SCC configuration, the effects of different parameters on the removal of F− and Cl− were investigated including current density, hydraulic residence time (HRT), activated carbon (AC) loading and feed concentration of coexisting NaCl. Results indicated that the steady-state effluent Cl− concentration dropped with elevated applied current, and the decreasing rate got faster with the increase of HRT or AC loading. However, for the steady-state effluent F− concentration, it dropped to a value under a small applied current and maintained stable in spite of the increase in applied current, and both HRT and AC loading had insignificant effects on the steady-state effluent F− concentration. F− was preferentially removed from the treated water compared with Cl−, and a higher ion selectivity could be obtained at lower applied current and smaller HRT with the trade-off being that operation under these circumstances would generate outlet water with little change in conductivity compared to the influent. The removal efficiencies of F− and Cl− both decreased with increasing feed concentration of coexisting NaCl. This study should be of value in establishing FCDI as a viable technology for treatment of fluoride-contaminated brackish groundwater. [Display omitted] •Utilizing FCDI to treat fluoride-contaminated brackish groundwater is quite effective.•SCC was the most advantageous among the three operational modes of SCC, SC and ICC.•F− was preferentially removed compared to Cl− with a high ion selectivity achievable.•Steady-state effluent F− and Cl− concentrations versus current are greatly different.
ISSN:0048-9697
1879-1026
DOI:10.1016/j.scitotenv.2021.150166