Superiority of 68Ga-FAPI PET/CT scan in detecting additional lesions compared to 18FDG PET/CT scan in breast cancer
Purpose We compared the ability of 68 Ga-FAPI PET//CT with 18 FDG PET/CT imaging techniques to detect additional lesions in breast cancer patients that may affect further chemotherapy options. Methods A total of 48 patients with breast cancer underwent concurrent 68 Ga-FAPI-04 and 18 FDG PET/CT rega...
Gespeichert in:
Veröffentlicht in: | Annals of nuclear medicine 2021-12, Vol.35 (12), p.1321-1331 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
We compared the ability of
68
Ga-FAPI PET//CT with
18
FDG PET/CT imaging techniques to detect additional lesions in breast cancer patients that may affect further chemotherapy options.
Methods
A total of 48 patients with breast cancer underwent concurrent
68
Ga-FAPI-04 and
18
FDG PET/CT regardless of whether they had received chemotherapy or not in the last month before imaging. Both modalities were compared according to various parameters: clinical/pathological features, number of lesions detected, activity uptake (SUV
max
), and the effect on the evaluation of response to treatment in the post-chemotherapy group.
Results
This retrospective study included 48 patients with breast cancer (mean age 53.3 ± 11.7 years; IDC 89.6%; ILC 10.4%). In the comparison of both modalities, no statistical significance was obtained in terms of the pathological characteristics of the patients. More lesions were demonstrated in all categorized regions in
68
Ga-FAPI PET/CT imaging with higher uptake values compared to
18
FDG PET/CT in this study. In the treatment response evaluation of the post-chemotherapy group, 12 cases (12/24) who were evaluated as PMR, CMR, or SD according to
18
FDG PET/CT results were later accepted as PD due to newly detected lesions in complementary
68
Ga-FAPI PET/CT imaging and treatment of patients was managed accordingly by clinicians.
Conclusion
It was determined that
68
Ga-FAPI PET/CT was superior to
18
FDG PET/CT in terms of accuracy and it was thought that
68
Ga-FAPI PET/CT could be utilized as an additional complementary imaging to
18
FDG PET/CT. Moreover,
68
Ga-FAPI PET/CT, with its significant theranostic potential, could become a key element in predicting the pathological response of breast cancer patients in further researches. |
---|---|
ISSN: | 0914-7187 1864-6433 1864-6433 |
DOI: | 10.1007/s12149-021-01672-x |