Differential-pulse anodic-stripping voltammetric determination of traces of lead in high-purity copper after its separation by ion exchange
Trace amounts of lead in copper can be determined by differential-pulse anodic-stripping voltammetry after separating it from the matrix. Lead was quantitatively retained on a small Dowex 1-X4 ion-exchange column, without retaining copper when present as a copper-amine complex in solutions containin...
Gespeichert in:
Veröffentlicht in: | Analytica chimica acta 1990, Vol.231 (1), p.133-136 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Trace amounts of lead in copper can be determined by differential-pulse anodic-stripping voltammetry after separating it from the matrix. Lead was quantitatively retained on a small Dowex 1-X4 ion-exchange column, without retaining copper when present as a copper-amine complex in solutions containing 0.2 M sodium hydroxide. Subsequent desorption was done with 2 M nitric acid. After deposition for 1 min on a hanging mercury drop electrode and subsequent stripping, the limit of detection was 2 ng ml−1 and the limit of quantification was 6.6 ng ml−1. Recoveries of lead were checked by standard addition to copper solution. |
---|---|
ISSN: | 0003-2670 1873-4324 |
DOI: | 10.1016/S0003-2670(00)86408-9 |