Complex Repair of a Completely Fused Nullicuspid Aortic Valve Late in Adolescence
We report a case of an 18-year-old female who presented with severe aortic stenosis and insufficiency, eight years following resection of a subaortic membrane. On echocardiography, she was found to have a completely fused or nullicuspid valve, with three equal sinuses and three commissural fusions....
Gespeichert in:
Veröffentlicht in: | World journal for pediatric & congenital heart surgery 2021-11, Vol.12 (6), p.790-793 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report a case of an 18-year-old female who presented with severe aortic stenosis and insufficiency, eight years following resection of a subaortic membrane. On echocardiography, she was found to have a completely fused or nullicuspid valve, with three equal sinuses and three commissural fusions. Aortic valve repair included leaflet tricuspidization, three commissurotomies, trileaflet ring annuloplasty, and pericardial leaflet reconstruction. At one year follow-up, the patient is asymptomatic, with stable gradients. |
---|---|