Novel Core–Shell Polyamine Phosphate Nanoparticles Self‐Assembled from PEGylated Poly(allylamine hydrochloride) with Low Toxicity and Increased In Vivo Circulation Time

An approach for reducing toxicity and enhancing therapeutic potential of supramolecular polyamine phosphate nanoparticles (PANs) through PEGylation of polyamines before their assembly into nanoparticles is presented here. It is shown that the number of polyethylene glycol (PEG) chains for polyamine...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Small (Weinheim an der Bergstrasse, Germany) Germany), 2021-09, Vol.17 (35), p.e2102211-n/a
Hauptverfasser: Andreozzi, Patrizia, Simó, Cristina, Moretti, Paolo, Porcel, Joaquin Martinez, Lüdtke, Tanja Ursula, Ramirez, Maria de los Angeles, Tamberi, Lorenza, Marradi, Marco, Amenitsch, Heinz, Llop, Jordi, Ortore, Maria Grazia, Moya, Sergio Enrique
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An approach for reducing toxicity and enhancing therapeutic potential of supramolecular polyamine phosphate nanoparticles (PANs) through PEGylation of polyamines before their assembly into nanoparticles is presented here. It is shown that the number of polyethylene glycol (PEG) chains for polyamine largely influence physico‐chemical properties of PANs and their biological endpoints. Poly(allylamine hydrochloride) (PAH) are functionalized through carbodiimide chemistry with three ratios of PEG molecules per PAH chain: 0.1, 1, and 10. PEGylated PAH is then assembled into PANs by exposing the polymer to phosphate buffer solution. PANs decrease size and surface charge with increasing PEG ratios as evidenced by dynamic light scattering and zeta potential measurements, with the ten PEG/PAH ratio PANs having practically zero charge. Small angle X‐ray scattering (SAXS) proves that PEG chains form a shell around a polyamine core, which is responsible for the screening of positive charges. MTT experiments show that the screening of amine groups decreases nanoparticle toxicity, with the lowest toxicity for the 10 PEG/PAH ratio. Fluorescence correlation spectroscopy (FCS) proves less interaction with proteins for PEGylated PANs. Positron emission tomography (PET) imaging of 18F labelled PANs shows longer circulation time in healthy mice for PEGylated PANs than non‐PEGylated ones. PEGylated polyamines are assembled into nanoparticles by complexation with phosphate ions. PEGylated polyamine nanoparticles show a core–shell structure with an external PEG layer as shown by small angle X‐ray scattering and display almost no charge. PEGylated polyamine phosphate nanoparticles show lower toxicity and longer circulation time in vivo than non‐PEGylated ones.
ISSN:1613-6810
1613-6829
DOI:10.1002/smll.202102211