Comparison of CAIPIRINHA-accelerated 3D fat-saturated-SPACE MRI with 2D MRI sequences for the assessment of shoulder pathology
Objectives To compare the performance of 6-min MRI with a fat-saturated 3D-controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) Sampling perfection with application-optimized contrast using different flip angle evolution (SPACE) TSE protocol with 10-min 2D TSE MRI prot...
Gespeichert in:
Veröffentlicht in: | European radiology 2022, Vol.32 (1), p.593-601 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objectives
To compare the performance of 6-min MRI with a fat-saturated 3D-controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) Sampling perfection with application-optimized contrast using different flip angle evolution (SPACE) TSE protocol with 10-min 2D TSE MRI protocol for assessment of abnormalities of the shoulder.
Methods
Forty-nine subjects underwent both 3D fat-saturated-CAIPIRINHA SPACE and 2D TSE sequences of the shoulder on a 3.0-T system. Following randomization and anonymization, two musculoskeletal radiologists evaluated the 2D and 3D images independently for image quality and diagnostic capability. Descriptive statistics, inter-observer, and inter-method concordance were investigated.
p
values < 0.05 were considered significant.
Results
For image quality assessment, 2D images were similar to 3D CAIPIRINHA SPACE images (
p
= 0.05). 3D had lower noise standard deviation (SD) and higher fluid CNR than 2D images (
p
= 0.00). For diagnostic capability assessment, using 2D TSE as a standard of reference, sensitivity, specificity, and accuracy of 3D SPACE were, respectively, 94.81%, 94.12%, and 94.39% for tendon abnormalities; 97.06%, 80.00%, and 91.84% for acromioclavicular joint abnormalities; 88.89%, 100.00%, and 93.89% for adjacent bone alterations; and 97.30%, 100%, and 97.96% for joint fluid/effusion assessment. The inter-method concordance was moderate to almost perfect. The inter-observer-concordance of the shoulder assessment was also moderate to almost perfect, with SSP lesions demonstrating the greatest concordance.
Conclusions
The performance of 6-min 3D fat-saturated-CAIPIRINHA SPACE MRI for shoulder MRI is similar to that of 10-min 2D TSE MRI. 3D fat-saturated-CAIPIRINHA SPACE MRI can be utilized to reduce scan time without degradation in image quality.
Key Points
•
CAIPIRINHA acceleration 3D fat-saturated-MRI of the shoulder is achievable in 6 min with high spatial resolution.
•
3D fat-saturated CAIPIRINHA MRI is similar to 2D MRI in the shoulder assessment.
•
3D CAIPIRINHA MRI images enable rapid diagnosis of shoulder abnormalities without image quality degradation. |
---|---|
ISSN: | 0938-7994 1432-1084 |
DOI: | 10.1007/s00330-021-08183-3 |