Fixed-dose prothrombin complex concentrate for emergent warfarin reversal among patients with intracranial hemorrhage
Four-factor prothrombin complex concentrate (4PCC) is the preferred reversal agent for warfarin reversal, although the ideal dose is unknown. Fixed-dose 4PCC offers simplified dosing compared to standard-dosing algorithms with potentially lower risks of thromboembolic complications given lower doses...
Gespeichert in:
Veröffentlicht in: | The American journal of emergency medicine 2021-11, Vol.49, p.326-330 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Four-factor prothrombin complex concentrate (4PCC) is the preferred reversal agent for warfarin reversal, although the ideal dose is unknown. Fixed-dose 4PCC offers simplified dosing compared to standard-dosing algorithms with potentially lower risks of thromboembolic complications given lower doses are typically utilized.
Retrospective, observational, multicentered, pre- post- study of patients who received 4PCC for warfarin reversal among four hospitals within the same regional health system. Standard-dose patients received variable doses ranging from 25 to 50 units/kg based on total body weight and initial INR and fixed-dose patients received 2000 units. The primary outcome was achievement of a target INR ≤ 1.4 on the first post-4PCC INR result.
After exclusions, 48 and 42 patients were analyzed in the standard-dose and fixed-dose groups, respectively. There was no difference in the ability to achieve a target INR of ≤1.4 (82.6% vs 81.5%, p = 0.14). Both groups received the same median dose of 2000 units, although fixed-dose patients actually received a higher weight-based dose than standard-dose patients (27 units/kg vs 24.5 units/kg).
A fixed-dose 4PCC regimen of 2000 units among patients with ICH was as effective as standard-dose 4PCC for INR reversal among patients with ICH. However, fixed-doses of 2000 units at times exceeded standard 4PCC doses which may be contradictory to the goals of fixed-dose 4PCC for warfarin reversal. |
---|---|
ISSN: | 0735-6757 1532-8171 |